3-wire

View:

eYc THM06 Industrial Accuracy Temp. & Humidity Transmitter

Input : Capacitive humidity sensor & Pt100
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Range : -40°C ... +180°C
Customized up to 200°C (Optional)
0 ... 100%RH (non-condensing)
Accuracy : [Temperature]±0.15°C+0.002°C x tactual
[Humidity (0 ... 90%)]Nonlinear error:±1.2%RH, Hysteresis error:±0.8%RH, Repeatability error:±0.4%RH
[Humidity (90 ... 100%)]±2%RH
IP rating : IP67
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06C-A Thermal Mass Air Velocity and Air Volume Transmitter

Output:4 ... 20 mA & RS-485 / 0 ... 10 V & RS-485 / RS-485 & Impulse
Input:Pt20/Pt300 (Air velocity) / Pt1000 (Temp.)
Measuring range:0 ... 5 m/s ~ 0 ... 60 m/s
Accuracy:±1.5% (Option±1%)
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc PMD330 Differential Pressure Transmitter (Indoor)

Feature:Silicon chips on differential pressure module of MEMS integration technology
Input:Piezoelectric differential pressure module
Output:4 ... 20 mA / 0 ... 10 V
Measuring range:±50 ... ±10000 pa
Accuracy:±2.0% of F.S.
Display:Optional

eYc FTM06T-W Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Range: Water 0 ... 1.5 m/s;0 ... 3 m/s
Accuracy: ±3% 0 ... 1.5 m/s;±5% 1.5 ... 3 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc PHM33 Industrial Differential Pressure Transmitter

Range:0 ... 500 pa
Input:Thermo differential pressure module​
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V /1 ... 5 V / 2 ... 10 V / 0 ... 10 V​
Accuracy:± 0.5 % of F.S.
Display:Optional

eYc THS07 Temperature & Humidity Transmitter for Probe Type

Feature : Industrial class sensor comes with high accuracy and long-term stability
Input : Capacitive Humidity Sensor & Pt100
Output : Temperature RTD(Pt100 / NTC10K);Humidity 0 ... 10 V;4 ... 20 mA
Accuracy : Temperature ±0.3°C+ 0.002°Cx tactual / Humidity(at +25°C) ±3%RH(30 ... 70%RH) of F.S. /
Humidity(at +15 ... 35°C) ±5%RH(20 ... 80%RH) of F.S.
Measuring range : Temperature 0 ... 50°C;Humidity 5 ... 95%RH
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM84/85 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Features:LCD, display air velocity and temperature
Sensor Type:Thermal mass flow sensor
Air Velocity Measuring Range:0.15 ... 90 m/s
Air Velocity min. Measuring Range:0.15 m/s
Temp. Sensor / Measuring Range:Pt1000, 0 ... 80°C
Accuracy(+25°C):Air velocity:±1.5%F.S.
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS17 Temperature and Humidity Transmitter (Digital / Analog)

MOQ:50 PCS/YEAR
Feature : Semiconductor MEMS sensor, has nicer long-term stability of measuring and react quickly feature
Output : Digital / Analog / RS-485 ; 4...20mA (2-wire) ; 0...10V(3-wire)
Range : 0 ... 50 °C ; 0 ... 100 %RH(non-cond.)
Accuracy : ± 0.5 °C ; ± 5 %RH
Nice Stability : Non-cond. : Sensor Protected
Housing : SUS304 or PC Fire-proof
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THM80X Series Industrial High Accuracy Temp. & Humidity Transmitter

Input:Capacitive Humidity Sensor & Pt100 Ω A class
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Measuring range:
THM801:-40 ... +80°C / THM802:-40 ... +120°C / THM803:-40 ... +200°C(as request) ; 0 ... 100%RH;-40 ... +60dp°C
Accuracy(at+25°C):
Temperature : ±0.15°C±0.002°Cxtactual
Humidity ( 0 ... 90 %RH ) : Nonlinear error:±1.2%RH / Hysteresis error:±0.8%RH / Repeatability error:±0.4%RH
Humidity ( 90 ... 100 %RH) : ±2%RH
IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS30X Series Multifunction Temp. & Humid. Transmitter(Wall type/Duct/Remote/Outdoor)

Features:Industrial sensor comes with high accuracy and long-term stability
Input:Capacitive humidity sensor & Pt 100 class A
Output:RS-485 or 2 analog output / 4 ... 20 mA / 0 ... 10 V
Linear accuracy(at 25°C):Temperature ±0.2°C±0.005°Cxtactual / Humidity (at+25°C)±2%RH
Operating range suggestion:Temperature 0 ... 50°C(THS301);- 40 ... + 80°C(THS302 / 304 / 307) / Humidity 0 ... 100%RH
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc PMD33 Differential Pressure Transmitter (Indoor)

Feature:Silicon chips on differential pressure module of MEMS integration technology
Input:Piezoelectric differential pressure module
Output:4 ... 20 mA / 0 ... 10 V
Measuring range:±50 ... ±2500 pa
Accuracy:±2.0% of F.S.
Display:Optional