CDA system / Equipment / Factory

View:

eYc FTM06C-A Thermal Mass Air Velocity and Air Volume Transmitter

Output:4 ... 20 mA & RS-485 / 0 ... 10 V & RS-485 / RS-485 & Impulse
Input:Pt20/Pt300 (Air velocity) / Pt1000 (Temp.)
Measuring range:0 ... 5 m/s ~ 0 ... 60 m/s
Accuracy:±1.5% (Option±1%)
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

HUBA 692 differential pressure transmitter

Range:0 ... 0.1 - 25 bar

PR 3102 Pt100 converter

Schmidt SS 20.261 Flow Sensor

eYc FTM84/85 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Features:LCD, display air velocity and temperature
Sensor Type:Thermal mass flow sensor
Air Velocity Measuring Range:0.15 ... 90 m/s
Air Velocity min. Measuring Range:0.15 m/s
Temp. Sensor / Measuring Range:Pt1000, 0 ... 80°C
Accuracy(+25°C):Air velocity:±1.5%F.S.
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

Schmidt IL30 Mass Flow Sensor

HUBA 520 Relative Pressure Transmitter

Range:-1 ... 9 bar / 0 ... 2.5 - 1000 bar

Schmidt SS 20.600 Flow Sensor

eYc DPM02 Multifunction Signal Display Monitor

Feature:Measuring input type : DC current / DC voltage, more output type:Analog output / Relay / RS-485, extraction of square root(Input : voltage, current)
Display readout:5 digits(-9.9.9.9 ... +9.9.9.9.9), 7-segment display
Accuracy:0.1%F.S.±1 digital
Input&Output:Current / Voltage

HUBA 528 OEM type Pressure Transmitter

Range:-1 ... 0 – 60 bar (relative pressure) / 0 ... 1 – 16 bar (absolute pressure)

eYc TP04 2-wire Temperature Transmitter for Duct Type

Feature:SS Housing, all-in design with anti-condensation function and good heat dissipation
Input:RTD Pt100 Ω
Output:DC 4 ... 20 mA((2-wire)
Temp. range:-50 ... +50°C / 0 ... 50°C / 0 ... 100°C / 0 ... 200 °C / Special span
Accuracy:±0.5% of F.S.
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Industrial High Pressure Low Humidity Dew Point Transmitter

Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA