Chemical / Pharmaceutical / Food industry / Medical biotechnology

View:

eYc FTM06C-A Thermal Mass Air Velocity and Air Volume Transmitter

Output:4 ... 20 mA & RS-485 / 0 ... 10 V & RS-485 / RS-485 & Impulse
Input:Pt20/Pt300 (Air velocity) / Pt1000 (Temp.)
Measuring range:0 ... 5 m/s ~ 0 ... 60 m/s
Accuracy:±1.5% (Option±1%)
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

HUBA 699 differential pressure transmitter

Range:-1 ... 1 mbar / 0 ... 0.3 - 50 mbar

HUBA 692 differential pressure transmitter

Range:0 ... 0.1 - 25 bar

EGE SN450 Serise Flow Sensors

Range:Water 1 … 150 cm/s; Oil 3 … 300 cm/s
Output:Realy
Medium temperature:-20 … +80℃
Compressive strength:100 bar
IP rating:IP65 / IP67

PR 5104B Ex Repeater / Power Supply

PR 4114 Universal Transmitter

PR 5333A 2-wire Programmable Transmitter

Schmidt SS 20.415 Flow Sensor

Dinel ULM-70 Ultrasonic Level Meters

eYc FTM84/85 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Features:LCD, display air velocity and temperature
Sensor Type:Thermal mass flow sensor
Air Velocity Measuring Range:0.15 ... 90 m/s
Air Velocity min. Measuring Range:0.15 m/s
Temp. Sensor / Measuring Range:Pt1000, 0 ... 80°C
Accuracy(+25°C):Air velocity:±1.5%F.S.
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THM80X Series Industrial High Accuracy Temp. & Humidity Transmitter

Input:Capacitive Humidity Sensor & Pt100 Ω A class
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Measuring range:
THM801:-40 ... +80°C / THM802:-40 ... +120°C / THM803:-40 ... +200°C(as request) ; 0 ... 100%RH;-40 ... +60dp°C
Accuracy(at+25°C):
Temperature : ±0.15°C±0.002°Cxtactual
Humidity ( 0 ... 90 %RH ) : Nonlinear error:±1.2%RH / Hysteresis error:±0.8%RH / Repeatability error:±0.4%RH
Humidity ( 90 ... 100 %RH) : ±2%RH
IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM94/95 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Feature:Suitable for harsh environments, industrial processes flow monitoring or slightly corrosion compressed air
Input type:Pt20 / Pt300(Air velocity),Pt1000(Temp.)
Measuring range:0 ... 120 Nm/s
Output signal:4 ... 20 mA / 0 ... 10 V / RS-485 / Impulse
Accuracy:±1.5%
Installation:Duct type / Remote type
IP rating:IP67