Controller / Indicator / Monitor

View:

CARLO SMS31 Safety modules

Inputs
Number of safety channels:2
Safety inputs (contact inputs):S11-S12 and S21-S22
Loop resistance:Max. 1 kΩ
Input current:Typical 5 mA

Outputs
NO safety outputs:3
NC auxiliary output:1
Type:Voltage free contact output, relays with forcibly guided contacts

GREISINGER Universal conductivity meter GMH 3431

Measuring range:Conductivity 0.0..200.0 μS / cm / 0..2000 μS / cm / 0.00..20.00 mS / cm / 0.0..200.0 mS / cm / 0..400 mS / cm (only GMH 3451) / Manually adjustable or AutoRange
Spec. resistance:0.005..100.0 kOhm * cm
Salinity:0.0..70.0 g / kg water
TDS:0..1999 mg/l

FLUIDWELL M853 Data Acquisition & Communication Module

Signal Inputs
‧4 (isolated) analog inputs.
‧3 digital status-/pulse inputs.
‧1 potentiometer input.
‧Modbus communication protocol (RS485 / RS232).
‧SDI-12 communication protocol.
Data outputs
‧GPRS data communication through TCP, FTP and/or email.
‧Full control through the web-portal or the Process View software.
‧Process alarms and system alerts by SMS.

FLUIDWELL N410 DIN Panel mount - Batch Controller

Input:Flowmeter / Status
Output:Pulse / Alarm / Control
Operating temperature / humidity:-20°C ... +60°C / 85% non-condensing, relative.
Power Supply:24V DC / 10 – 230V AC
Communication:RS232 or RS485 2-wire

FLUIDWELL F190 Intrinsically Safe - Multi Purpose Monitor

Input:4 ... 20mA
Output:Alarm / Analog
Ambient temperature:-40°C ... +70°C
Power Supply:Long life Lithium battery / 4 ... 20 mA Loop-powered / 8 ... 24 V AC/DC / 115 ... 230V AC
Explosion Proof:ATEX

PR 4501 Display/Programming Front ( for 4114/4116/4131)

Modification of operational parameters in system 4000 and 9000
devices
Fixed display for visualisation of process data and status
Password protection
Scrolling help text in 7 languages
Clicks on to the front of the device mounted in the process

Huba 801 Digital indicating devices

Input signals : 0 ... 5 V / 0 ... 10 V / 0 ... 20 mA / 4 ... 20 mA

GREISINGER Finest manometer GMH 3161-07

GREISINGER Differential pressure unit GMH 3161-13

eYc DPM02 Multifunction Signal Display Monitor

Display readout:5 digits(-9.9.9.9 ... +9.9.9.9.9)
Input:Current / Voltage
Analog output:Current / Voltage
Accuracy:0.1%F.S.±1 digital
IP rating:IP65(Front panel)

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA(2-Wire) / 0 ... 10V(3-Wire)
Electrical connection: DIN 43650: 330° / M12: 210°
Accuracy: 0.2%F.S.
Display: On-site display / 4 ... 20 mA / 0 ... 10V