eYc FTM06C-A Thermal Mass Air Velocity and Air Volume Transmitter

Output:4 ... 20 mA & RS-485 / 0 ... 10 V & RS-485 / RS-485 & Impulse
Input:Pt20/Pt300 (Air velocity) / Pt1000 (Temp.)
Measuring range:0 ... 5 m/s ~ 0 ... 60 m/s
Accuracy:±1.5% (Option±1%)
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc P041 Pressure Transmitter

Output : 4 … 20 mA
Measuring range :10 bar ( Relative pressure )
Linear accuracy : ±0.3% of F.S.
Power supply : DC 10 ... 30 V
IP rating : IP65 (DIN 43650)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM94/95 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Feature:Suitable for harsh environments, industrial processes flow monitoring or slightly corrosion compressed air
Input type:Pt20 / Pt300(Air velocity),Pt1000(Temp.)
Measuring range:0 ... 120 Nm/s
Output signal:4 ... 20 mA / 0 ... 10 V / RS-485 / Impulse
Linear accuracy:±1.5%
Installation:Duct type / Remote type
IP rating:IP67
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTS14 Thermal Air Velocity Transmitter

Features :Temperature compensation, linear adjustment function
Sensor : Thermal mass flow sensor
Measuring range : 20 m/s
Minimum measuring range : 0.2 m/s
Accuracy: ±5% F.S.
Signal : 4 ... 20 mA / DC 0 ... 10 V
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTS34/35 Air Velocity Transmitter

Features:Linear calibration function
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc GS43/44 CO2 Transmitter(Indoor / Duct Type)

Feature: Accurate and excellent long-term life cycle. Measuring up to 10000 PPM
Sensor type:NDIR sensor
Output:4 ... 20 mA / 0 ... 10 V
linear accuracy(at +25°C):400 ... 2000 PPM:±40 PPM ±3% of reading / 2000 ... 10000 PPM:±250 PPM ±3% of reading
Measuring range : 2000 / 5000 / 10000 PPM
Display : Optional

eYc THS130/140 Temperature & Humidity Transmitter for Indoor / Duct type

Input:MEMS sensor
Output:4 ... 20 mA / 0 ... 10 V
Signal connection:2-wire / 3-wire
Accuracy:± 0.5°C / ±5%RH(30 ... 80%RH)
Measuring range:0 ... 50°C / 0 ... 100%(Non-condensing)

●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

Made in Taiwan​

eYc THS13/14 Temperature & Humidity Transmitter Wall type / Duct type

MOQ:100 PCS/YEAR
Input type : Capacitive Humidity Sensor & Pt1000 Ω
Measuring Range : 0 ... 50°C ; 0 ... 100%RH
Accuracy ( at 25 °C ) : ±0.3°C+0.002°C x tactual ; ±3%RH(20 ... 80%)
Output : 4 ... 20mA / 2-wire
IP Rating : IP54(Sensor:IP20)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )

eYc P063 Differential Pressure Transmitter

Feature:Welding and full-sealed construction, full stainless housing, compact size, easy installation
Sensor type:Piezoresistive Diaphragm
Measuring range:0 ... 20 bar
Output:4 … 20 mA
Signal connection:2-wire
Accuracy:±0.5% of F.S.
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA