Sensor:inductive
Mechanical Connection:female thread G 3/8, G 1 / male thread G 3/8 A, G 1 A / hose nozzle Ø11, Ø30
Pressure resistance:PN 16 bar
Medium temperature:0..60 °C
Ingress protection:IP 67
Sensor:biased Hall sensor
Nominal width:DN 15..50
Process connection:male thread G 1/2 A...G 2 A
Metering ranges:1.8..1133 l/min
Measurement accuracy:±1 % of full scale value
Medium temperature:-20..+85 °C / optionally -20..+150 °C (for 8 bar min.)
Ambient temperature:-20..+70 °C
Instrument SL-Pt eco
Measuring range:-200.0..+250.0 °C
Resolution:0.1°C
Accuracy:
at -20.0..+100.0 °C :±0.1 °C ±1 digit
at -70.0..+200.0 °C :±0.1 % of m.v. ±2 digit
Protection class:IP65 / IP67
Measuring range:Conductivity 0.0..200.0 μS / cm / 0..2000 μS / cm / 0.00..20.00 mS / cm / 0.0..200.0 mS / cm / 0..400 mS / cm (only GMH 3451) / Manually adjustable or AutoRange
Spec. resistance:0.005..100.0 kOhm * cm
Salinity:0.0..70.0 g / kg water
TDS:0..1999 mg/l
Measuring range : 0.00..14.00 pH
Output signal : 4..20 mA, (2-wire) / 0..10 V (3-wire)
Working temperature : 0..50 °C
Accuracy : 0.02 pH ±1 digit
Ingress protection : IP65
Output:4 ... 20 mA
Operating ambient temperature:-30/+55°C UR 90%.
Standard working temperature:up to 105°C
Maximum working pressure:50 Bar
Minimum degree of protection:IP65