● Universal flow rate sensor with dynamic diaphragm
● Analog output, two switching outputs
● Clear, easily legible, illuminated LCD display
● Modifiable units in the display
● Designed for industrial use
● Small, compact construction
● Simple installation
Sensor : dynamic diaphragm
Nominal width : DN 8..25
Process connection : female thread G1/4..G 1,
Metering ranges 1..100 l/min (water) ; minimum value range 0.4..6 l/min
Accuracy :
Standard ranges:
±3 % of the measured value, minimum 0.25 l/min
Minimum value range :
±3 % of the measured value,minimum 0.1 l/min
Pressure resistance :
Plastic construction: PN 16 bar
Full metal construction: PN 100 bar
Media temperature : 0..+70 °C (option 0..150 °C)
Ambient temperature : 0..+70 °C
Supply voltage : 18..30 V DC
Power consumption : < 1 W
Ingress protection IP 67