Metal housing

View:

eYc THM14EX EX-Series Temp. and Humidity Transmitter

Feature : Stable & Accurate Performance in Explosion Hazardous Areas
Input : Capacitive Humidity Sensor & Pt 1000
Output : 4 ... 20 mA
Range : -20 ... +80°C ; 0 ... 100 %RH
Accuracy : ±0.3°C ; ±2% RH
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc P041 Pressure Transmitter

Output : 4 … 20 mA
Measuring range :10 bar ( Relative pressure )
Linear accuracy : ±0.3% of F.S.
Power supply : DC 10 ... 30 V
IP rating : IP65 (DIN 43650)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THM06 Industrial Accuracy Temp. & Humidity Transmitter

Input : Capacitive humidity sensor & Pt100
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Range : -40°C ... +180°C
Customized up to 200°C (Optional)
0 ... 100%RH (non-condensing)
Accuracy : [Temperature]±0.15°C+0.002°C x tactual
[Humidity (0 ... 90%)]Nonlinear error:±1.2%RH, Hysteresis error:±0.8%RH, Repeatability error:±0.4%RH
[Humidity (90 ... 100%)]±2%RH
IP rating : IP67
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06C-A Thermal Mass Air Velocity and Air Volume Transmitter

Output:4 ... 20 mA & RS-485 / 0 ... 10 V & RS-485 / RS-485 & Impulse
Input:Pt20/Pt300 (Air velocity) / Pt1000 (Temp.)
Measuring range:0 ... 5 m/s ~ 0 ... 60 m/s
Accuracy:±1.5% (Option±1%)
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T-W Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Range: Water 0 ... 1.5 m/s;0 ... 3 m/s
Accuracy: ±3% 0 ... 1.5 m/s;±5% 1.5 ... 3 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

Huba 681 Pressure level transmitter

HONSBERG VM-…GR (Ex) Flow monitor

HUBA 620/625 Relative pressure switch

HUBA 501 Pressure transmitter

HONSBERG Flow monitor MR

HONSBERG OMNI-T Temperature transmitter

HONSBERG OMNI-P1 Pressure transmitter with LCD