eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS30X Series Multifunction Temperature & Humidity Transmitter (indoor/duct/remote/outdoor)

Features : Multifunction physical quantities ─
temperature & humidity / dew point / frost point /
wet-bulb temp. / vapor pressure /mixture ratio /
absolute humidity / specific enthalpy
Input : Capacitive Humidity Sensor & PT 100Ω class A
Output : standard RS-485 or 2 analog output
( 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V )
Linear Accuracy (at 25°C) :
temperature ± 0.2 °C ± 0.005 °C x t actua /
humidity ( at + 25 °C ) ± 2 %RH
Working Range Suggestion :
temperature 0 ... 50 °C ( THS301 );
- 40 ... + 80 °C ( THS302 / S304 / 307 ) /
humidity : 0 ... 100 %RH / dew point - 40 ... + 60 °C /
Other please refer to physical quantity measuring range list
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc TGP03_THP03 Multifunction PM2.5 Indoor Air Quality Monitor

Features : Real-Time Data of PM2.5, CO2, temperature & humidity. / Anti-condensation and nicer long-term stability.
Input : Temp.&Humidity MEMS / CO2 : NDIR / PM2.5: Infrared LED
Output : RS-485
Accuracy : ± 0.5 ℃ / ± 5 %RH ( at 30 ... 80 %RH ) /
CO2 ± 40 PPM ± 3 % of Reading / PM2.5 ± 10 μg/m3 ± 5% of Reading
Measuring Range : Temp.: 0 ... 50 ℃ / Humidity :0 ... 100 %RH ( non-cond. ) /
CO2: 0 ... 2000 PPM / PM2.5: 0 ... 500 μg/m3
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc GM33/GM34 CO Transmitter Wall / Duct Type

Features : Electrochemical Sensor with a long life,good long term stability and high accuracy. It has lower sensitivity to interferant gases.
Input : Electrochemistry CO Sensor
Output : 0~1V / 0~5V / 0~10V / 1~5V / 0~20mA /
4~20mA ; RS-485;RS-485 & analogue
linear accuracy ( at 25 ± 2 ℃, 40 ± 10 % RH ) :
± 3 % of F.S. ( best zero-point )
Measuring range : on request
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc GS23 CO2 Transmitter / Indoor type

Features : Data can be logged and transferred to pc via RS-485 function link free software. 1 analog output or Modbus RS-485. Optional LCD display.
Input : NDIR sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at +25 °C ;101.3 kPa ) : ± 40 PPM ± 3 % of reading
Measuring Range : 0 ... 2000 PPM
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THS13/14 Temperature & Humidity Transmitter Indoor/ Duct

Input type : Capacitive Humidity Sensor & PT1000Ω
Measuring Range : 0 ... 50°C ; 0 ... 100 %
Accuracy ( at 25 °C ) : ±0.3°C+0.002°C x tactual ; ±3% RH(20 ... 80 %)
Output : 4 ... 20mA / 2-wire
IP Rating : IP54(Sensor:IP20)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc PMD33 Differential Pressure Transmitter

Feature :
Input : Piezoelectric Differential Pressure Module
Output : 0 ... 20mA / 4 ... 20mA / 0 ... 5V / 0 ... 10V
Range : ± 50 ... ± 2500 pa
Accuracy : ± 2.0 % of F.S.
Display : Optional

eYc GS43/44 CO2 Transmitter Indoor / Duct Type

Features : Measuring up to 10000 PPM.Voltage or current output and optional RS-485, and display.Free software configuration
Input : NDIR sensor
Output : 4 ... 20mA / 0 ... 20mA / 0 ... 10V / 0 ... 5V / 0 ... 1V
linear accuracy ( at +25 °C ) :
400 ... 2000 PPM:± 40 ppm ± 3 % of reading /
other : ± 50 PPM ± 3 % of reading
measuring range : 2000 / 5000 / 10000 PPM
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc PHM33 Differential Pressure Transmitter

Feature :
Input : Thermo Differential Pressure Module
Output : 0 ... 20mA/4 ... 20mA / 0 ... 1V/0 ... 5V/1 ... 5V/2 ... 10V /0 ... 10V
Range : 0 ... 500 pa
Accuracy : ± 0.5 % of F.S.
Display : Optional

eYc THG03 CO2 Temperature & Humidity Transmitter / Indoor type

Features : Integrated 3 sensors in 1 device with optional LCD display Measuring temperature, humidity and carbon dioxide.2 Analog outputs or Modbus RS-485.Optional Analog output + RS-485.
Input : CO2 NDIR sensor / Temp. & humidity MEMS sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at +25 °C ;V = 24 VDC;101.3kPa ) :
CO2 ± 40 PPM ± 3 % of reading / Temperature ± 0.5 ℃ /
Humidity ± 5 % RH ( 30 ... 80 % RH )
Measuring Range : CO2 0 ... 2000 PPM / Temp. 0 ... 50 ℃ /
Humidity 0 ... 100 %RH ( non-cond.)
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THR23 Temperature & Humidity Transmitter for indoo

Features : 2 analog outputs or Modbus RS-485 /
Optional analog output + RS-485 /
Data can be logged and transferred to pc via RS-485 function link free software
Input Sensor Type : Temp.&Humidity MEMS sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at + 25°C ; V = 24VDC ) :
Temperature ± 0.5 ℃ / Humidity ± 5 %RH ( at 30 ... 80 %RH )
Measuring Range :
Temperature 0 ... 50 ℃ / Humidity 0 ... 100 %RH ( non-cond. )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THS130/140 Temperature & Humidity Transmitter for Indoor / Duct type

Features : Voltage or current outputs, optional passive temperature output
Input : MEMS sensor
Output : 4 ... 20 mA / 0 ... 10V
Signal Connection : 3-wire
Accuracy : ± 0.5°C / ± 5% RH ( 30....80 %RH )
Measuring Range : 0 ... 50 °C / 0 ... 100 % (non-condensing)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)