eYc THM06 Industrial High Temperature Multi-function Dew Point Transmitter 【Preliminary】

Feature : Adaptation to high temperature and high humidity conditions or harsh environments such as chemical pollution & condensation
Input : ​Capacitive humidity sensor & Pt100
Measurement range : ​-40 ... +120°C ;
Customized up to 150°C (optional) ;
0 ... 100%RH (non-cond.) ; -50 ... +60dp°C
Output: ​4 ... 20mA / 0 ... 10V / RS-485
Signal connection : 3-wire
Accuracy :±0.15°C+0.002°C x t actual ;
0 ... 100%RH (non-cond.) ; ±3dp°C ± (0.02%F.S./°C)

eYc THS88 Plus High Pressure Dew Point Transmitter

Features :Speed Upgrade 150%
Input : Capacitive humidity sensor & PT 100 Ω
Output : Standard RS-485 & 1 analog output
Pressure resistance : 16 bar
Working range of dew point : -60 ... +60 dp °C
Linear accuracy : ±2 dp °C
Max. Scaling range : Dew point : -100 ... +60dp℃

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS30X Series Multifunction Temperature & Humidity Transmitter (indoor/duct/remote/outdoor)

Features : Multifunction physical quantities ─
temperature & humidity / dew point / frost point /
wet-bulb temp. / vapor pressure /mixture ratio /
absolute humidity / specific enthalpy
Input : Capacitive Humidity Sensor & PT 100Ω class A
Output : standard RS-485 or 2 analog output
( 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V )
Linear Accuracy (at 25°C) :
temperature ± 0.2 °C ± 0.005 °C x t actua /
humidity ( at + 25 °C ) ± 2 %RH
Working Range Suggestion :
temperature 0 ... 50 °C ( THS301 );
- 40 ... + 80 °C ( THS302 / S304 / 307 ) /
humidity : 0 ... 100 %RH / dew point - 40 ... + 60 °C /
Other please refer to physical quantity measuring range list
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc TGP03_THP03 Multifunction PM2.5 Indoor Air Quality Monitor

Features : Real-Time Data of PM2.5, CO2, temperature & humidity. / Anti-condensation and nicer long-term stability.
Input : Temp.&Humidity MEMS / CO2 : NDIR / PM2.5: Infrared LED
Output : RS-485
Accuracy : ± 0.5 ℃ / ± 5 %RH ( at 30 ... 80 %RH ) /
CO2 ± 40 PPM ± 3 % of Reading / PM2.5 ± 10 μg/m3 ± 5% of Reading
Measuring Range : Temp.: 0 ... 50 ℃ / Humidity :0 ... 100 %RH ( non-cond. ) /
CO2: 0 ... 2000 PPM / PM2.5: 0 ... 500 μg/m3
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc GM33/GM34 CO Transmitter Wall / Duct Type

Features : Electrochemical Sensor with a long life,good long term stability and high accuracy. It has lower sensitivity to interferant gases.
Input : Electrochemistry CO Sensor
Output : 0~1V / 0~5V / 0~10V / 1~5V / 0~20mA /
4~20mA ; RS-485;RS-485 & analogue
linear accuracy ( at 25 ± 2 ℃, 40 ± 10 % RH ) :
± 3 % of F.S. ( best zero-point )
Measuring range : on request
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc GS23 CO2 Transmitter / Indoor type

Features : Data can be logged and transferred to pc via RS-485 function link free software. 1 analog output or Modbus RS-485. Optional LCD display.
Input : NDIR sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at +25 °C ;101.3 kPa ) : ± 40 PPM ± 3 % of reading
Measuring Range : 0 ... 2000 PPM
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc FTM8485 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THS13/14 Temperature & Humidity Transmitter Indoor/ Duct

Input type : Capacitive Humidity Sensor & PT1000Ω
Measuring Range : 0 ... 50°C ; 0 ... 100 %
Accuracy ( at 25 °C ) : ±0.3°C+0.002°C x tactual ; ±3% RH(20 ... 80 %)
Output : 4 ... 20mA / 2-wire
IP Rating : IP54(Sensor:IP20)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

HONSBERG RRI Flow transmitter

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc TP04 2-wire Temperature Transmitter for Duct Type

Features : SS housing, all-in design with anti-condensation function and good heat dissipation.
Good measuring repeatability and anti-interference.
Input : PT100Ω
Output : 4 ... 20mA ; 2-wire
Accuracy : ± 0.5 % of F.S.
Temperature Range : -50...+ 50 ° C / - 50...0 ° C / 0...50 ° C / 0...100 ° C/ 0...200 ° C or special range