Air velocity transmitter
Air velocity transmitters are available to meet a wide range of airflow measurement requirements, from low air velocities as low as 0.1 m/s to high-speed airflow reaching 200 m/s. Certain models can also provide volumetric airflow information based on duct cross-sectional area and configuration settings. Depending on the model, available interfaces include 4 ... 20 mA and 0 ... 10 V analog outputs, as well as RS-485 digital communication. Selected industrial-grade models are suitable for operating conditions involving high temperatures, high pressures, dust, or specific gases, subject to individual product specifications. Applications include HVAC systems, compressed air systems, and various industrial air velocity monitoring requirements.
Air velocity transmitters are available to meet a wide range of airflow measurement requirements, from low air velocities as low as 0.1 m/s to high-speed airflow reaching 200 m/s. Certain models can also provide volumetric airflow information based on duct cross-sectional area and configuration settings. Depending on the model, available interfaces include 4 ... 20 mA and 0 ... 10 V analog outputs, as well as RS-485 digital communication. Selected industrial-grade models are suitable for operating conditions involving high temperatures, high pressures, dust, or specific gases, subject to individual product specifications. Applications include HVAC systems, compressed air systems, and various industrial air velocity monitoring requirements.
eyc-tech AFMC HVAC Average Flow Measuring Tube
Features : Multi-hole averaging design for stable HVAC duct measurement down to 1 m/s with the PMM330.
Operating pressure : 1 bar
Operating temperature : 0 ... 80°C
Length : 100 ... 1000 mm
eyc-tech FDM06-L Bi-directional Low Air Flow Thermal Mass Transmitter (Laminar flow / Overflow type)
Features : Ultra-low flow detection with reverse flow alert
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : ±(0.00 ... 2 m/s)
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.05 ... 1.00 m/s : ±(1% of mv+0.05 m/s), 0.05 ... 2.00 m/s : ±(1% of mv+0.1 m/s)
IP rating : IP65
eyc-tech FDM06-L Bi-directional Low Air Flow Thermal Mass Transmitter (Duct / Remote type)
Features : Bi-directional transmitter for tight-space insertion
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : ±(0.00 ... 1 m/s), ±(0.00 ... 2 m/s), ±(0.00 ... 10 m/s), ±(0.00 ... 30.00 m/s)
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.05 ... 1.00 m/s:±(1% of mv+0.05 m/s), 0.05 ... 2.00 m/s:±(1% of mv+0.1 m/s), 0.1 ... 10.00m/s:±(1% of mv+0.2 m/s), 0.5 ... 30.00m/s:±(1% of mv+0.5 m/s)
IP rating : IP65
eyc-tech FDM06-P Average Flow Thermal Mass Transmitter
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.5 ... 60 m/s:±(1.5% of mv + 0.8 m/s)
IP rating : IP65
eyc-tech AFMP Average Flow Measuring Tube (Pitot tube)
Features : Multi-point averaging. Suitable for large pipes. Resistant to high temperature and corrosion.
Operating pressure : Standard type : Max. 10 bar / High-temp. type : Max. 4 bar
Operating temperature : Standard type : Max. 200°C / High-temp. type : Max. 600°C
Length : 2" ... 40"(50 ... 1000 mm)
eyc-tech FTM94/95 Industrial High Accuracy Thermal Air Velocity Transmitter
Features : Designed for industrial application. Air flow measurement up to 120 m/s. Resistant to high temperature, high pressure, dust, and corrosion.
Sensor type : Pt20 / Pt300(Air velocity) / Pt1000(Temp.)
Measuring range : 0 ... 120 Nm/s
Output : 4 ... 20 mA / 0 ... 10 V / RS-485 / Impulse
Accuracy : 0 ... 40 m/s : ±(1% of mv+0.5 m/s), 40 ... 60 m/s : ±(1% of mv+1 m/s), 90 ... 120 m/s : ±(1% of mv+1.5 m/s)
IP rating : IP67(Probe) / IP65(Housing)
eyc-tech FTM06D Thermal Mass Flow Transmitter
Features : Suitable for compressed dry air system.
Sensor type: Thermal mass flow sensor meter
Measuring range: 0 ... 120 m/s
Output: 4 ... 20 mA / 0 ... 10 V / RS-485 / Frequency / Pulse
Accuracy: 0 ... 5 m/s : ±(1% of mv+0.06 m/s), 5 ... 10 m/s : ±(1% of mv+0.1 m/s), 20 ... 40 m/s : ±(1% of mv+0.5 m/s), 60 ... 90 m/s : ±(1% of mv+1 m/s), 90 ... 120 m/s : ±(1% of mv+1.5 m/s)
IP rating: IP65
eyc-tech FTS34/35 Air Velocity Transmitter
Features : Suitable for light industry. High accuracy and high stability.
Sensor type : Thermal mass flow sensor
Measuring range : 0 ... 40 m/s
Output : 4 ... 20 mA / DC 0 ... 10 V
Accuracy : 0 ... 2 m/s : ±(1% of mv+0.1 m/s), 0 ... 10 m/s : ±(1% of mv+0.15 m/s), 0 ... 20 m/s : ±(1% of mv+0.4 m/s), 0 ... 40 m/s : ±(1% of mv+0.6 m/s)
IP rating : IP54
eyc-tech FTM84/85 Industrial High Accuracy Thermal Air Velocity Transmitter
Features : Suitable for clean air; Resistant to high pressure and high temperature.
Sensor type : Thermal mass flow sensor
Measuring range : 0 ... 90 m/s
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : 0 ... 2 m/s : ±(1% of mv+0.06 m/s), 5 ... 10 m/s : ±(1% of mv+0.1 m/s), 20 ... 40 m/s : ±(1% of mv+0.5 m/s), 60 ... 90 m/s : ±(1% of mv+1 m/s)
IP rating : IP67
eyc-tech AFMT Average Flow Measuring Tube ( Pitot tube )
Features : Multi-point averaging. Suitable for large pipe. Resistant to high temperature, and corrosion.
Operating pressure : Max.10 bar
Operating temperature : Max.250°C
Length : 4" ... 40"(100 ... 1000 mm)
eyc-tech FTS140 Hot Wire Air Velocity Transmitter
Features : Economic model for HVAC application.
Sensor type : Hot wire mass flow transmitter
Measuring range : 0 ... 20 m/s
Output : 4 ... 20 mA / DC 0 ... 10 V
Accuracy : ±3% F.S.
IP rating : IP54
Schmidt SS 23.700-EX Flow Sensor
Medium to be measured: Standard: air or nitrogen / Optional: biogas, methane, natural gas, argon, COs, special gases and mixtures and others (on request)
Measuring range wN: 0 ... 220 m/s
Output: Analog / Pulse
Operating temperature: -20 ... +120 °C
Operating overpressure (max.): 16 bar
Type of protection: IP66 (housing), IP67 (sensor probe) / II 3G Ex ec ic IIC T4 Gc / II 3D Ex ic tc IIIC 135°C Dc
Schmidt SS 20.651 Flow Sensor
Medium :Clean air / nitrogen / other gases upon request
Measuring range : 0 ... 60 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : 0 ... +350°C
Accuracy:±3% of measured value +(0.4% of final value; min. 0.08 m/s)
Operating pressure : Atmospheric / 16 bar (over pressure)
Type / class of protection:IP 65 (housing) / IP 54 (probe) / III (SELV) or PELV (EN 50178)
Schmidt SS 20.600 Flow Sensor
Medium :Air or nitrogen; optional: Methan, natural gas, biogas, CO2, oxygen and specialty gases and gas mixtures
Measuring range : 0 ... 220 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : -20 … +120°C; SS 20.600 EX: -40 ... +120 °C
Accuracy:±3% of measured value + (0.4 % fmr; min. 0.08 m/s)
Operating pressure : 16 / 40 bar; oxygen (O2 > 21 %: 20 bar)
Type / class of protection:IP 65 (housing), IP 67 (sensor) / III (SELV) or PELV
Schmidt IL30 Mass Flow Sensor
Measuring range:0 ... 712 Nm³/h
Operating temperature:-20 … +60 °C
Measuring accuracy flow:± (3 % of measured value + 0.3 % fmr)
Measuring accuracy temperature:≤ ±2 °C (at mass flow > 2 % fmr)
Output 1 (OUT 1):4 … 20 mA volume flow
Output 2 (OUT 2):4 ... 20 mA temperature of medium