Flow transmitter

Flow transmitters and flow meters are suitable for monitoring liquid and gas flow in piping systems. Available measurement technologies include thermal mass, ultrasonic, vortex, and Coriolis methods, along with flow switch options. Suitable models can be selected based on fluid properties, flow range, piping conditions, output requirements, and operating environment. These products support flow monitoring in equipment and industrial processes.

Flow transmitters and flow meters are suitable for monitoring liquid and gas flow in piping systems. Available measurement technologies include thermal mass, ultrasonic, vortex, and Coriolis methods, along with flow switch options. Suitable models can be selected based on fluid properties, flow range, piping conditions, output requirements, and operating environment. These products support flow monitoring in equipment and industrial processes.

eyc-tech FDM09-I Venturi Thermal Mass Flow Meter (Liquid / Air)

Feature: Bypass Venturi flow path design with high sensitivity, low pressure loss, and stable repeatability, supporting simultaneous flow and liquid temperature measurement
Sensor Type: Hot-wire sensor
Turndown Ratio: 50 : 1
Measuring Range: DN15: 42 L/min, DN25: 150 L/min, DN32: 250 L/min, DN40: 380 L/min, DN50: 600 L/min
Output: 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy: ±1% F.S.
IP Rating: IP65

eyc-tech FTC06 Temperature and Flow Transmitter

Features : Thermal mass measurement of flow and temperature with RS-485, ideal for continuous liquid cooling monitoring in data centers.
Sensor type : PT sensor
Measuring range : 0 ... 3 m/s (Water), 0 ... 60 m/s (Air)
Output : 4 ... 20 mA / RS-485 / NPN
Repeatability : ±0.5%
Accuracy : Water ±(1% mv + 0.05 m/s), Air ±(1% mv + 0.5 m/s)
IP rating : IP65, IP67 (Option)

eyc-tech FUM06 Ultrasonic Flowmeter

Features : Non-intrusive and high-precision measurement, suitable for various fluids and pipe sizes.
Sensor type : Ultrasonic time difference
Turndown ratio : 100 : 1
Measuring range : 0.1 ... 10 m/s
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±1% F.S.
IP rating : IP65

Huba 237 Vortex flow sensor

Measuring range : 1,1 ... 240 l/min
Medium temperature : -15 ... 125°C (Non-freezing media)
Media : Heating water with standard additives; Drinking water
Accuracy : <1 % FS(<50% measuring range end value Water);<2%(Measured value)(>50% measuring range end value Water)
Electrical connection : M12x1 connector

Huba 210 Flow sensor for liquid media

Measuring range : 0,5 ... 150 l/min
Response time : 5 ... 500 ms
Media : Heating water with standard additives; Drinking water
Medium temperature : -15 ... 125 °C (Non-freezing media)

EGE SZAb 400 Flow Sensors

Output:Relay/change-over
Supply voltage:AC 230 V ±10%
Ex marking-GAS:II(1)GD [Ex ia] IIC
Ex marking-Dust:II(1)GD [Ex ia] IIIC

EGE SD 504 S Flow rate sensors

Medium:Water
Detection range:1 ... 1000 ml/min (0.001 ... 1 l/min)
Compressive strength:20 bar
Ambient temperature:-20 ... 70 °C
Protection rating:IP 67

EGE SDN 500 Series Flow Sensors

Output:PNP / Relay / Analog
Medium temperature:0...+80°C
Compressive strength:1 ... 20 bar
Protection:IP67

EGE SKM 420 GR/GA Flow Sensors

Output:Relay / PNP / 4 … 20 mA
Supply voltage :DC 24 V ±20%
Ambient temperature:-20 … +60℃
IP rating:terminal: IP 20 / housing: IP 40

EGE SC 440/1-A4-GSP Flow Sensors

Detection range:water 1...150 / oil 3...300 cm/s
Output:PNP
Sensor length L:48 mm
Thread:G1/2

EGE LNZ 450 GA-S Air Flow Sensors

Range:0.5 ... 30 m/s
Output:4 ... 20 mA
Medium temperature:-20 … +80°C
Compressive strength:30 bar
IP rating:IP67

EGE LN 520 GA Air Flow Sensors

Range : 0.5 ... 15 m/s
Output : 4 ... 20 mA
Medium : Air, non-explosive gas
Ambient temperature : -20 … +70°C
IP rating : IP67

Rheonik RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

MEASUREMENTS:Mass Flow / Volumetric Flow / Density / Temperature
FUNCTIONS:Batch / Filling Control / Standard Volume Gas Flow / Assurance Factor® / API std. Volume, Net Oil / Tamperproof Lock Switch
OUTPUTS:2 x Analog / 2 x Frequency / Pulse / 2 x Digital Status
INPUTS:2 x Digital / 1 x Analog
INTERFACES:PC USB / RHECom / RS-485 / Modbus RTU / HART over analog
APPROVALS:ATEX / IEC Ex / CSA

Rheonik RHM20 Industrial Coriolis Mass Flow Meter

TYPICAL APPLICATION RANGE:2.25 up to 300 kg/min
MAX. PRESSURE:799 bar / 11588 psi
TEMPERATURE:-196 up to +400°C
ACCURACY:0.1% of rate
MATERIALS:316Ti / 904L / Alloy C22 / Tantalum / more on request
PROCESS CONNECTIONS:1″ up to 3″