Explosion proof

Industrial explosion-proof instruments and transmitters are designed for specified hazardous locations where flammable gases or combustible dust may present an explosion risk. Available products cover pressure, level, flow, temperature, air velocity, and temperature and humidity measurement. The product range also includes explosion-proof signal converters, safety barriers, and proximity switches. Suitable products can be selected based on measurement requirements, operating environment, explosion-protection markings, hazardous area classification, and certification requirements.

Industrial explosion-proof instruments and transmitters are designed for specified hazardous locations where flammable gases or combustible dust may present an explosion risk. Available products cover pressure, level, flow, temperature, air velocity, and temperature and humidity measurement. The product range also includes explosion-proof signal converters, safety barriers, and proximity switches. Suitable products can be selected based on measurement requirements, operating environment, explosion-protection markings, hazardous area classification, and certification requirements.

Huba 525 industrial pressure transmitter

Medium : Liquids and gases
Pressure range : 0 ... 0.05 – 0.6 bar
Output : 0 ... 5 V, 0 ... 10 V, 4 ... 20 mA, ratiom. 10 ... 90%
Accuracy : ± 0.35% fs

Huba 520 Relative Pressure Transmitter

Medium : Liquids, gases and refrigerants (incl. ammonia)
Pressure range : -1 ... 9 bar / 0 ... 2.5 – 1000 bar
Output : 0 ... 5 V, 1 ... 6 V, 0 ... 10 V, ratiom. 10 ... 90% , 4 ... 20 mA
Accuracy : typ. <0.3% FS

Huba 681 Level transmitter

Measuring range : 0 ... 0.1 – 25 bar
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Media : Diesel oil / Fuel oil / Kerosene / Salt water / Brackish water / Drinking water / Potable / Lake water / River water / Benzene / Chlorinated water
Cable : PUR / PE / Teflon

EGE SZAb 400 Flow Sensors

Output:Relay/change-over
Supply voltage:AC 230 V ±10%
Ex marking-GAS:II(1)GD [Ex ia] IIC
Ex marking-Dust:II(1)GD [Ex ia] IIIC

PR 9106B HART transparent repeater

• 24 VDC supply via power rail or connectors
• Active and passive mA input
• Active or passive output via the same two terminals
• Splitter function - 1 in and 2 out
• SIL3 Full Assessment and certified acc. to IEC 61508

PR 5333D 2-wire Programmable Transmitter

Input:RTD / Ohm
Ouput: 4...20 mA
Accuracy:Better than 0.1% of sel. range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal): IP68 / IP00

PR 9116B Universal Converter

Input:RTD / TC / Ohm / Potentiometer / mA / V
Output:Active / passive mA output and relay
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20

PR 5437D 2-wire HART 7 temperature transmitter

Input:RTD / TC / Potentiometer / Ohm / mV
Output:3.8...20.5 / 20.5...3.8 mA
Operating temperature:-50°C ... +85°C
Accuracy:< ±0.1% of span
Protection degree (encl./terminal):IP68 / IP00

PR 5335D 2-wire transmitter with HART protocol

Input:RTD / TC / Ohm / mV
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00

PR 5202B Pulse Isolator

Sensor types:NAMUR according to EN 60947-5-6 / mechanical contact
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20

Schmidt SS 23.700-EX Flow Sensor

Medium to be measured: Standard: air or nitrogen / Optional: biogas, methane, natural gas, argon, COs, special gases and mixtures and others (on request)
Measuring range wN: 0 ... 220 m/s
Output: Analog / Pulse
Operating temperature: -20 ... +120 °C
Operating overpressure (max.): 16 bar
Type of protection: IP66 (housing), IP67 (sensor probe) / II 3G Ex ec ic IIC T4 Gc / II 3D Ex ic tc IIIC 135°C Dc

Schmidt SS 23.400 Flow Sensor

Medium :Clean air / Nitrogen / Additional gases on request
Measuring range : 0 ... 20 m/s
Output :0 … 10 V / 4 ... 20 mA(for option ATEX not for sensor length 130 mm)
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Protection type / protection class:IP 66/III (SELV) or PELV (EN 50178)

Schmidt SS 20.500 Flow Sensors

Medium :Air / nitrogen or other gases on request
Measuring range : 0 ... 50 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : -40 ... +85°C
Accuracy:±(3% of measured value + [0.4% of end of measuring range; min. 0.02 m/s])
Operating pressure : Compact sensor 10 bar (overpressure) / Remote sensor atmospheric (700 hPa … 1,300 hPa)
Type / class of protection:IP67 (sensor head) / IP65 (housing) / III (SELV) or PELV

Galltec KC.Ex / GC.Ex Humidity and Temperature Sensor with ATEX Certificate

Measuring element:Pt 100 class B
Measuring range:-20...+80°C / 0 … 100%RH
Output:4...20 mA
Accuracy at 23°C:Humidity ±2%rh, other ranges ±0.3 K / Temperature ±0.2 K, other ranges ±0.3 K
Operating temperature:-40...+80°C
Degree of protection:IP65

Dinel ULM-53 Ultrasonic Level Meters

Measuring range:0.1 ... 20 m
Output:4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy:0.3% / 0.2% / 0.15%
Supply voltage:DC 18 ... 36 V / DC 18 ... 30 V
Ambient temperature range:-30 ... +70°C
Protection class:IP67 / IP68