Air Velocity Automation QC Technology Development
- Index
- Solutions
- Technology
- Air Velocity Automation QC Technology Development
Automatic Quality Control Testing Technology and Wind Tunnel Calibration System for Air Velocity Sensors
Yuden Control Technical Document | Development of Automatic QC Testing Technology for Air Velocity Sensors
In industrial processes, automation control, and environmental monitoring applications, air velocity and airflow measurement accuracy play a critical role in system performance. To ensure that air velocity sensors maintain stable and reliable measurement results across different measurement ranges, Yuden Control Technology has collaborated with the Institute of Automation and Control at National Taiwan University of Science and Technology through industry–academia cooperation to develop an automatic quality control testing system for air velocity sensors. By integrating automated testing and wind tunnel calibration technology, this system improves the quality and measurement consistency of air velocity measurement equipment.
The system establishes a complete evaluation procedure based on IEC 61298 and ISO 17025 standards. Through different measurement cycles and test point configurations, three-cycle or five-cycle curve testing can be performed to establish the measurement characteristic curve of air velocity sensors. This allows linear calibration and measurement error analysis to be carried out, ensuring high accuracy and repeatability across various airflow ranges.
In addition, Yuden Control Technology has established a professional air velocity calibration laboratory. Using precision wind tunnel equipment, the laboratory provides high-accuracy air velocity calibration services. The current calibration range covers 0.25 ~ 60 m/s, with an expanded uncertainty of 0.04 m/s ~ 0.90 m/s. This enables high-precision measurement services for both industrial and research applications, while providing traceable calibration and testing reports.
Automatic QC Testing System Architecture for Air Velocity Sensors
This system integrates wind tunnel calibration equipment with automated measurement systems to establish a complete automatic quality control testing process for air velocity sensors. It significantly improves measurement efficiency and testing consistency.
- Wind tunnel test chamber capable of precisely controlling airflow velocity
- PC-based automated air velocity control and QC testing human–machine interface
- Automatic generation of air velocity QC testing reports
- Integration of precision wind tunnel equipment for product calibration and factory inspection reports
Three-Cycle Calibration Curve Testing for Air Velocity Sensors
During the calibration process of air velocity sensors, multi-point airflow measurement combined with cyclic testing can establish a complete measurement characteristic curve. The following example shows a three-cycle curve test. The results demonstrate strong consistency between the tested sample accuracy and the reference standard source, effectively verifying the measurement accuracy and stability of the air velocity sensor.
Technical Presentation on Air Velocity Calibration and Wind Tunnel Testing
- System architecture design
- Open-loop wind tunnel system introduction
- Quality control testing and evaluation procedures
- System operation workflow and measurement charts
Download the complete technical document
FAQ
What is air velocity sensor calibration?
Air velocity sensor calibration is performed by comparing the tested sensor with a standard airflow source (typically a wind tunnel system). By comparing the sensor output with reference measurement equipment, a calibration curve between the sensor output and the actual airflow velocity can be established, ensuring measurement accuracy and traceability.
How does a wind tunnel calibration system work?
A wind tunnel calibration system generates a stable and controllable airflow environment. Through multi-point measurement and cyclic testing, the difference between the sensor output and the reference airflow velocity is analyzed. Linear calibration and error analysis are then performed to ensure high accuracy of air velocity sensors across different measurement ranges.
Why do air velocity sensors require regular calibration?
During long-term operation, air velocity sensors may experience measurement drift due to environmental conditions, sensor aging, or contamination. Regular calibration ensures measurement accuracy and maintains stable operation of industrial process control and environmental monitoring systems.