Huba 511 pressure transmitter
Measuring range : -1 ... 0 – 600 bar
Response time : <2 ms (typ. 1 ms)
Media : Liquids and gases
Ambient temperature : <125°C
Electrical connection : M12x1 / AMP / DIN / Cable
Features
The compact pressure transmitters of Type 511 meet the highest demands in terms of robustness, accuracy, temperature stability, and EMC properties. They are therefore suitable for use in a wide range of industrial applications.
•Compact and robust design for maximum operational safety
•No media leakage when exceeding burst pressure
•Minimal temperature influences on accuracy
•Excellent EMC properties
•Time-saving, fast customer-side cable assembly with quick cable screw connection
Specification
| Product feature | |
|---|---|
| Pressure measuring range | -1 ... 0 – 600 bar |
| Media stop system | Media stop system to prevent media from escaping if the bursting pressure range is exceeded. (> 40 bar nominal pressure) |
| Response time | <2 ms (typ. 1 ms) |
| Load change | <100 Hz |
| Sensor weight | 85; 95 g |
| Field of application | |
| Media | Liquids and gases |
| Permissible overload | 2,5 x FS (max. 900 bar); 3 x FS |
| Bursting pressure | 2,5 x FS (max. 900 bar); 3 x FS |
| Ambient condition | |
| Ambient temperature | <125 °C |
| Material | |
| Housing | Stainless steel 1.4305 (AISI 303) |
| Measuring element with media contact | Ceramic Al2O3 (96 %) |
| Pressure connection with media contact | Stainless steel 1.4305 (AISI 303) |
| Media stop system with media contact | PPS |
| Sealing material with media contact | FPM; EPDM; NBR; FPM spez. |
| Electrical data | |
| Current consumption | <20 mA |
| Inverse-polarity protection | Short-circuit and reverse polarity protected. Each connection against each other with max. supply voltage. |
| Insulation voltage | 500; 1000 VDC |
| Electrical connection | Cable 1.5 m; Cable quick connector; AMP connector (Junior Power Timer); M12x1 connector plastic thread; M12x1 connector metal thread; Connector DIN EN 175301-803-C (industry standard 9.4 mm) |
| Installation guide | |
| Installation orientation | any |
| Approval | |
| EMC compatibility | CE-compliant in accordance with EN 61326-2-3 |
| UL | according to standard 61010-1 |
| Shock according to IEC 60068-2-27 | 100 g, 11 ms half sine wave, all 6 directions. Free fall from 2 m onto concrete (6x). |
| Permanent shock according to IEC 60068-2-29 | 40 g over 6 ms, 1000x all 3 directions. |
| Vibration according to IEC 60068-2-6 | 20 g, 2 ... 2000 Hz with amplitude ± 15 mm, 1 octave / minute in all 3 directions, 50 continuous loads. |
Download
Note : Design and specifications are subject to change without notice.
Note : Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.