Huba 501 Pressure transmitter
Measuring range : -1 ... 0 – 60 bar
Output : 4 ... 20 mA / 0 ... 10 V / 10 ... 90%(ratiometric)
Response time : <5 ms
Media : Liquids / Gases
Medium temperature : -15 ... 80°C
Permissible overload : 2 x FS (max. 80 bar)
Features
Type 501 pressure sensors are ideally suited for high-volume OEM projects in industrial automation thanks to semi-automated production. Various pressure connections and electrical connections are available with standardized output signals for easy system integration.
• Compact design
• Best price/performance ratio through automated production
• Rugged ceramic sensor technology
• High temperature resistance
• No mechanical creep
Specification
| Product feature | |
|---|---|
| Pressure measuring range | -1 ... 0 – 60 bar |
| Response time | <5 ms |
| Load change | <50 Hz |
| Sensor weight | 95 g; 110 g |
| Cable weight | 40 g |
| Field of application | |
| Media | Liquids and gases |
| Medium temperature | -15 ... 80°C |
| Permissible overload | 2 x FS (max. 80 bar) |
| Bursting pressure | 3 x FS (max. 90 bar) |
| Ambient condition | |
| Ambient temperature | -15 ... 80°C |
| Storage temperature | -40 ... 80°C |
| Material | |
| Housing | PA6 |
| Measuring element (with media contact) | Ceramic Al2O3 (96%) |
| Pressure connection (with media contact) | Stainless steel 1.4305 (AISI 303) |
| Sealing material (with media contact) | FPM; EPDM; NBR; MVQ |
| Electrical data | |
| Output (mA) | 4 ... 20 mA |
| Output (V) | 0 ... 10 V |
| Output (%) | 10 ... 90% (ratiometric) |
| Supply voltage | 5 VDC (±5%) |
| Current consumption | <20 mA |
| Inverse-polarity protection | Short-circuit and reverse polarity protected. Each connection against each other with max. supply voltage. |
| Installation guide | |
| Installation orientation | Recommendation: Pressure connections downwards |
| Approval | |
| EMC compatibility | CE-compliant in accordance with EN 61326-2-3 |
Download
Note : Design and specifications are subject to change without notice.
Note : Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.