Huba 528 IO-Link Relative Pressure Transmitter

Medium: Liquids and gases
Pressure range: -1 ... 0 - 60 bar
Output: IO-Link
Accuracy: <0.3%F.S.

Features

The compact type 528 pressure transmitter is based upon the well proven ceramic technology developed by Huba Control over 20 years ago. Huba Control offers with the Type 528 a universally applicable pressure transmitter with IO-Link communication technology. IO-Link is a standardized, digital point-to-point connection that allows the user to easily wire the unit and access a wide range of specific device and process data. IO-Link offers numerous possibilities for device diagnostics, allowing the status of the pressure transmitter to be continuously monitored. This makes the 528 IO-Link the ideal pressure transmitter for your Industry 4.0 application.

• Compact, rugged construction
• Communication via IO-Link 1.1 (Smart Sensor Profile ED2)
• Sensor diagnosis function
• High flexibility of process connections

Specification

Pressure range
Relative-1 ... 0 – 60 bar
Absolute0 ... 1 – 16 bar
Operating conditions
MediumLiquids; Gases
Medium temperatureFPM -15 ... +100°C
EPDM -40 ... +100°C
NBR -20 ... +100°C
MVQ -40 ... +100°C
FPM -40 ... +100°C
Ambient temperature-30 ... +85°C
Storage temperature-50 ... +100°C
Tolerable overload / Rupture pressure< 4 bar: 3.0 x fs
> 4 bar: 2.5 x fs
Materials
HousingStainless steel 1.4404 / AISI 316L
Plug accommodationPolyarylamide 50% GF UL 94 V-0
Pressure connectionStainless steel 1.4404 / AISI 316L; PVDF
SensorCeramic Al₂O₃ (96%)
Sealing materialFPM, EPDM, NBR, MVQ
Electrical overview
Output / Supply4 wire IO-Link 18 ... 33 VDC
Permanent current load100 mA per switching output
Current consumption< 15 mA (typ.)
Insulation voltage500 VDC
IO-Link
SpecificationV1.1
Port typeClass A
Baud rateCOM2 (38.4 k Baud)
Output functionPNP, NPN, PushPull
Dynamic response
Startup time50 ms
Response time< 2 ms (typ.)
Process cycle time< 3.3 ms
Load cycle< 100 Hz
Accuracy
Characteristic line± 0.3 % fs
Resolution0.1 % fs
Thermal characteristic± 0.2 % fs / 10K
Long term stability± 0.25 % fs
Approvals
EMCCE acc. EN 61326-2-3; EN 50121-3-2
ShockIEC 68-2-27
VibrationIEC 68-2-6
ULANSI/UL 61010-1 E325110
EACYes
Weight~ 90 g

Applications

Solar heating / CDU / In-Rack CDU / Circulation cooler / Large heat pumps / Water pumps / Water treatment / Mobile hydraulics / Industrial automation

Download

Note : Design and specifications are subject to change without notice.
Note : Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.