Huba 528 OEM type Pressure Transmitter

Medium : Liquids and gases
Pressure range : -1 ... 0 – 60 bar
Output : 0 ... 5 V, 1 ... 6 V, 0 ... 10 V, 4 ... 20 mA, ratiom. 10 ... 90%
Accuracy : typ. < 0.3% fs

Features

The compact type 528 pressure transmitter is based upon the well proven ceramic technology developed by Huba Control over 20 years ago. These transmitters are suitable for applications across a broad spectrum of industries.
​
• Compact, rugged construction
• Negligible temperature influence on accuracy
• Large selection of connections available
• Saving time by quick cable mounting by the customer with swift connector

Specification

Product Features
Pressure range
Relative: -1 ... 0 ... 60 bar
Absolute: 0 ... 1 ... 16 bar
Accuracy
Characteristic line a: ± 0.3% fs
Resolution: 0.1% fs
Thermal characteristic (max.): ± 0.2% fs / 10K
Long term stability acc. EN 60770-1 (max.): ± 0.25% fs
Operating Conditions
Medium
Liquids and gases
Temperature
Medium:
FPM: -15 ... +125 °C (-15 ... +120 °C)
EPDM: -40 ... +125 °C (-30 ... +120 °C)
NBR: -20 ... +100 °C
MVQ: -40 ... +125 °C (-30 ... +120 °C)
Ambient: -30 ... +85 °C (-25 ... +85 °C)
Storage: -50 ... +100 °C
Tolerable overload / Rupture pressure
< 4 bar: 3.0 x fs
> 4 bar: 2.5 x fs
Materials
Cover
Stainless steel 1.4404 / AISI 316L
Plug accommodation
Polyarylamide 50% GF UL 94 V-0
Materials in contact with medium
Pressure connection: Stainless steel 1.4404 / AISI 316L / PVDF
Sensor: Ceramic Al2O3 (96%)
Sealing material: FPM, EPDM, NBR, MVQ
Electrical Data
Output
2 wire: 4 ... 20 mA (7 ... 33 VDC / 10 ... 30 VDC)
3 wire: 0 ... 5 V; 1 ... 6 V; 0 ... 10 V; ratiom. 10 ... 90%
Load / Current consumption
Voltage outputs: > 10 kOhm / < 100 nF
Current consumption: < 7 mA (voltage output)
< 23 mA (4 ... 20 mA)
Polarity reversal protection
Short circuit proof and protected against polarity reversal.
Each connection protected against crossover up to max. supply voltage.
Insulation voltage
500 VDC
Response time
< 2 ms (1 ms typ.)
Load cycle < 100 Hz
Electrical connection
Swift connector (with or without cable 1.5 / 2.0 / 3.0 / 5.0 m)
Connector DIN EN 175301-803-A or C
Metri Pack 150 P2S Series
Connector M12x1
Braids
Connector RAST 2.5 (3 wire only)
Protection class
IP65 / IP67 depending on connection
Installation
Installation arrangement
Unrestricted
Recommendation: Pressure connection facing downwards
Approvals
EMC
CE conformity acc. EN 61326-2-3
Enhanced EMC protection EN 50121-3-2
Shock
IEC 68-2-27 100 g, 11 ms half sine wave
Vibration
IEC 68-2-6 20 g, 15 ... 2000 Hz
UL
ANSI/UL 61010-1 acc. E325110
Drinking water approval
NSF/ANSI 61 / 372 acc. MH60087
Explosion protection
Ex II 1/2 G Ex ia IIC T4 Ga/Gb
Ex II 1/2 D Ex ia IIIC T125°C Da/Db
ATEX / IECEx
Weight
~ 90 g

Applications

Solar heating / CDU / In-Rack CDU / Circulation cooler / Large heat pumps / Water pumps / Water treatment / Mobile hydraulics / Industrial automation

Download

Note : Design and specifications are subject to change without notice.
Note : Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.