Signal meter

Signal meters and instruments include signal converters, signal indicators, display controllers, signal isolators, and differential pressure signal processors. Depending on the model, these instruments can receive industrial input signals such as current, voltage, resistance temperature detector (RTD), and thermocouple (TC) signals. Available functions include 4 ... 20 mA and 0 ... 10 V analog outputs, relay outputs, and RS-485 digital communication. These products are suitable for signal conversion, indication, isolation, and equipment monitoring.

Signal meters and instruments include signal converters, signal indicators, display controllers, signal isolators, and differential pressure signal processors. Depending on the model, these instruments can receive industrial input signals such as current, voltage, resistance temperature detector (RTD), and thermocouple (TC) signals. Available functions include 4 ... 20 mA and 0 ... 10 V analog outputs, relay outputs, and RS-485 digital communication. These products are suitable for signal conversion, indication, isolation, and equipment monitoring.

PR 5714 Programmable LED Indicator

Display:4-digit 14-segment LED
Input:mA / V / Ohm / RTD / TC / Potentiometer
Output:2 relays and analog
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C … +60°C
Protection degree (mounted in panel):IP65 / Type 4X

PR 4114 Universal Transmitter

Input:RTD / TC / Ohm / potentiometer / mA / V
Output:Current / voltage
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C … +60°C
Protection degree:IP20

PR 9116B Universal Converter

Input:RTD / TC / Ohm / Potentiometer / mA / V
Output:Active / passive mA output and relay
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20

PR 6334A 2-wire Programmable Transmitter

Input:TC
Output:4…20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree:IP20

PR 5335D 2-wire transmitter with HART protocol

Input:RTD / TC / Ohm / mV
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00

PR 5334A 2-wire Programmable Transmitter

Input:TC
Output: 4...20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal):IP68 / IP00

PR 5202B Pulse Isolator

Sensor types:NAMUR according to EN 60947-5-6 / mechanical contact
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20

PR 4510 Display / programming front

Programming display for all past and present 4000 / 9000 series devices, 3000 series devices where applicable, and all versions of ConfigMate 4590
Monitor process value and status from the built-in display
Scrolling help text in 7 languages

PR 3108 Isolated repeater/splitter

Current input:Measurement range 0...23 mA
Current output:Signal range 0...23 mA
Accuracy:Better than 0.05%
Operating temperature:-25°C ... +70°C
Protection degree:IP20