Products

PR 6334A 2-wire Programmable Transmitter

Input:TC
Output:4…20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree:IP20

PR 5437D 2-wire HART 7 temperature transmitter

Input:RTD / TC / Potentiometer / Ohm / mV
Output:3.8...20.5 / 20.5...3.8 mA
Operating temperature:-50°C ... +85°C
Accuracy:< ±0.1% of span
Protection degree (encl./terminal):IP68 / IP00

PR 5335D 2-wire transmitter with HART protocol

Input:RTD / TC / Ohm / mV
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00

PR 5334A 2-wire Programmable Transmitter

Input:TC
Output: 4...20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal):IP68 / IP00

PR 5202B Pulse Isolator

Sensor types:NAMUR according to EN 60947-5-6 / mechanical contact
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20

PR 4510 Display / programming front

Programming display for all past and present 4000 / 9000 series devices, 3000 series devices where applicable, and all versions of ConfigMate 4590
Monitor process value and status from the built-in display
Scrolling help text in 7 languages

PR 3108 Isolated repeater/splitter

Current input:Measurement range 0...23 mA
Current output:Signal range 0...23 mA
Accuracy:Better than 0.05%
Operating temperature:-25°C ... +70°C
Protection degree:IP20

Schmidt SS 23.700-EX Flow Sensor

Medium to be measured: Standard: air or nitrogen / Optional: biogas, methane, natural gas, argon, COs, special gases and mixtures and others (on request)
Measuring range wN: 0 ... 220 m/s
Output: Analog / Pulse
Operating temperature: -20 ... +120 °C
Operating overpressure (max.): 16 bar
Type of protection: IP66 (housing), IP67 (sensor probe) / II 3G Ex ec ic IIC T4 Gc / II 3D Ex ic tc IIIC 135°C Dc

Schmidt SS 20.651 Flow Sensor

Medium :Clean air / nitrogen / other gases upon request
Measuring range : 0 ... 60 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : 0 ... +350°C
Accuracy:±3% of measured value +(0.4% of final value; min. 0.08 m/s)
Operating pressure : Atmospheric / 16 bar (over pressure)
Type / class of protection:IP 65 (housing) / IP 54 (probe) / III (SELV) or PELV (EN 50178)

Schmidt SS 20.600 Flow Sensor

Medium :Air or nitrogen; optional: Methan, natural gas, biogas, CO2, oxygen and specialty gases and gas mixtures
Measuring range : 0 ... 220 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : -20 … +120°C; SS 20.600 EX: -40 ... +120 °C
Accuracy:±3% of measured value + (0.4 % fmr; min. 0.08 m/s)
Operating pressure : 16 / 40 bar; oxygen (O2 > 21 %: 20 bar)
Type / class of protection:IP 65 (housing), IP 67 (sensor) / III (SELV) or PELV

Schmidt IL30 Mass Flow Sensor

Measuring range:0 ... 712 Nm³/h
Operating temperature:-20 … +60 °C
Measuring accuracy flow:± (3 % of measured value + 0.3 % fmr)
Measuring accuracy temperature:≤ ±2 °C (at mass flow > 2 % fmr)
Output 1 (OUT 1):4 … 20 mA volume flow
Output 2 (OUT 2):4 ... 20 mA temperature of medium

Schmidt SS 20.261 Flow Sensor

Medium : Air / nitrogen / other gases upon request (flammable gases are not allowed)
Measuring range : 0 ... 90 m/s
Output :4 ... 20 mA
Operating temperature : -20 ... +85°C
Accuracy : ±5% of measured value +0.4% of measuring range
Operating pressure : 0 … 10 bar
Type of protection:IP 66 / III or PELV

Schmidt SS 20.415 LED Flow Sensor

Medium :Clean air / nitrogen / additional gases on request
Measuring range : 0 ... 10 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Type / class of protections:IP 65/III (SELV or PELV EN 50178)

Schmidt SS 20.250 Flow Sensor

Medium:Air or nitrogen, other gases upon request
Measuring range:0 ... 1 / 10 / 20 m/s / selectable
Output:4 ... 20 mA / 0 ... 10 V
Operating temperature:-20 ... +70 °C
Accuracy:±(5% of measured value + [0.4% of final value; min. 0,02 m/s])
Operating pressure:Atmospheric (700 ... 1,300 hPa)
Ingress protection / protection class:IP 65 / III (SELV) or PELV

Schmidt SS 20.700 Flow Sensor

Medium: Standard: Air or nitrogen / Optional: Pure oxygen, argon, CO2 and others (on request)
Measuring range: 0 ... 220 m/s
Output: 0 ... 10 V / 4 ... 20 mA / Pulse
Operating temperature: -20 ... +120 °C
Operating pressure: 16 bar
Type of protection / Protection class: IP66 (housing), IP67 (sensor probe) / III (SELV) or PELV (according EN 50178)