Products
Schmidt SS 23.400 Flow Sensor
Medium :Clean air / Nitrogen / Additional gases on request
Measuring range : 0 ... 20 m/s
Output :0 … 10 V / 4 ... 20 mA(for option ATEX not for sensor length 130 mm)
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Protection type / protection class:IP 66/III (SELV) or PELV (EN 50178)
Schmidt SS 20.400 Flow Sensor
Medium :Clean air / Nitrogen / Additional gases on request
Measuring range : 0 ... 20 m/s
Output :0 … 10 V / 4 ... 20 mA(for option ATEX not for sensor length 130 mm)
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Protection type / protection class:IP 66/III (SELV) or PELV (EN 50178)
Schmidt SS 20.500 Flow Sensors
Medium :Air / nitrogen or other gases on request
Measuring range : 0 ... 50 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : -40 ... +85°C
Accuracy:±(3% of measured value + [0.4% of end of measuring range; min. 0.02 m/s])
Operating pressure : Compact sensor 10 bar (overpressure) / Remote sensor atmospheric (700 hPa … 1,300 hPa)
Type / class of protection:IP67 (sensor head) / IP65 (housing) / III (SELV) or PELV
Schmidt SS 20.260 Flow Sensor
Medium:Air or nitrogen, other gases upon requeste
Measuring range : 0 ... 60 m/s
Output : 0 ... 10 V / 4 ... 20 mA
Operating temperature : -20 ... +120°C
Accuracy : ±(5% of measured value + [0.4 % of final value; min. 0.02 m/s])
Operating pressure : Atmospheric (700 … 1.300 hPa)
Ingress protection/protection class:IP 65 / III or PELV
Galltec KC.Ex / GC.Ex Humidity and Temperature Sensor with ATEX Certificate
Measuring element:Pt 100 class B
Measuring range:-20...+80°C / 0 … 100%RH
Output:4...20 mA
Accuracy at 23°C:Humidity ±2%rh, other ranges ±0.3 K / Temperature ±0.2 K, other ranges ±0.3 K
Operating temperature:-40...+80°C
Degree of protection:IP65
Galltec HGMini Room Humidistat series
Measuring element:Polyga®-measuring element
Water resistant control range:40...90%RH
Allowable ambient temperature:0...60°C
lifetime:> 6.000 breaking cycles
Protective system:IP20
Galltec TFG80 Humidity Temperature Sensor
Measuring medium:Air / Pressureless / Non-aggressive
Measuring range:0 … 100%RH
Measuring element:Pt100 ref. DIN EN 60751
Accuracy:±0.5°C / >40%RH(±2.5%RH) / <40%RH(acc. to tolerance diagram)
Working temperature / humidity:-30°C … +80°C / 30 … 100%RH
Protective system:IP64
Galltec HG80 Humidistat Series
Measuring element:Polyga®-measuring element
Measuring medium:Air / Pressureless / Non-aggressive
Control range:40 ... 90% RH
Operating temperatur: 0...60°C
Accuracy: > 50% RH(± 3.5% RH) / < 50% RH(± 4% RH)
Protection:IP50
RH Systems CGS-240 Humidity Generator
Dew/Frost Point:-25 … 70 °C DP, -23 … 0 °C FP
Relative Humidity:10 … 95 %RH (5% RH optiona)
Flow Rate:5 … 20 SLPM (5 … 50 SLPM optional)
Chamber Temperature:-0 … 72 °C (-10 & +85 °C extended ranges optional)
Chamber Pressure:Ambient
Accuracy:Relative Humidity: 0.1 %RH or 0.5 % of indicated RH value / Dew/Frost Point ± 0.1 °C / Temperature ±0.03 °C
RH Systems G3 Frost Point Generator
Frost/Dew Point Range: -120 °C FP … + 10 °C DP
Saturation Temperature Control Range: -120 °C … +20 °C
Gas Flow Rate Range: 0 … 10 slpm
Saturation Pressure Control Range: Near ambient to 1 MPa (150 psia)
Accuracy :Frost/Dew Point ± 0.1 °C / Temperature ±0.05 °C / Pressure ±0.05% FS
RH Systems PT-12 Precision Thermometer
Measurement Ranges:Temperature -200…+660°C / Resistance 1…380 Ω
Measurement Performance ( For the range of -200…+250°C):Resolution 0.1 mK / Accuracy : ≤ ±2 mK @ 23 °C (95% confidence level, 1 year) / Temperature coefficient : 0.1 mK / °C
Standard Features:Available inputs : 12 Channels / Input type : Pt-100 and Pt-25 Platinum Resistance Thermometer (PRT), 4-wire, Supports Smart 4-wire PRTs
RH Systems 973 Dew Point Mirror
Measuring range:Frost/Dew Point -50…+20°C / %RH 5…100% / Temperature -50…+150°C
Accuracy:Frost/Dew point ±0.1°C / Temperature ±0.07°C
Reproducibility:Frost/Dew Point ± 0.05°C / Temperature ± 0.05°C
Operation temperature: -10…+40°C
Digital I/O: RS-232