Sensor type
Schmidt SS 20.261 Flow Sensor
Medium : Air / nitrogen / other gases upon request (flammable gases are not allowed)
Measuring range : 0 ... 90 m/s
Output :4 ... 20 mA
Operating temperature : -20 ... +85°C
Accuracy : ±5% of measured value +0.4% of measuring range
Operating pressure : 0 … 10 bar
Type of protection:IP 66 / III or PELV
Schmidt SS 20.415 LED Flow Sensor
Medium :Clean air / nitrogen / additional gases on request
Measuring range : 0 ... 10 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Type / class of protections:IP 65/III (SELV or PELV EN 50178)
Schmidt SS 20.250 Flow Sensor
Medium:Air or nitrogen, other gases upon request
Measuring range:0 ... 1 / 10 / 20 m/s / selectable
Output:4 ... 20 mA / 0 ... 10 V
Operating temperature:-20 ... +70 °C
Accuracy:±(5% of measured value + [0.4% of final value; min. 0,02 m/s])
Operating pressure:Atmospheric (700 ... 1,300 hPa)
Ingress protection / protection class:IP 65 / III (SELV) or PELV
Schmidt SS 20.700 Flow Sensor
Medium: Standard: Air or nitrogen / Optional: Pure oxygen, argon, CO2 and others (on request)
Measuring range: 0 ... 220 m/s
Output: 0 ... 10 V / 4 ... 20 mA / Pulse
Operating temperature: -20 ... +120 °C
Operating pressure: 16 bar
Type of protection / Protection class: IP66 (housing), IP67 (sensor probe) / III (SELV) or PELV (according EN 50178)
Schmidt SS 23.400 Flow Sensor
Medium :Clean air / Nitrogen / Additional gases on request
Measuring range : 0 ... 20 m/s
Output :0 … 10 V / 4 ... 20 mA(for option ATEX not for sensor length 130 mm)
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Protection type / protection class:IP 66/III (SELV) or PELV (EN 50178)
Schmidt SS 20.400 Flow Sensor
Medium :Clean air / Nitrogen / Additional gases on request
Measuring range : 0 ... 20 m/s
Output :0 … 10 V / 4 ... 20 mA(for option ATEX not for sensor length 130 mm)
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Protection type / protection class:IP 66/III (SELV) or PELV (EN 50178)
Schmidt SS 20.500 Flow Sensors
Medium :Air / nitrogen or other gases on request
Measuring range : 0 ... 50 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : -40 ... +85°C
Accuracy:±(3% of measured value + [0.4% of end of measuring range; min. 0.02 m/s])
Operating pressure : Compact sensor 10 bar (overpressure) / Remote sensor atmospheric (700 hPa … 1,300 hPa)
Type / class of protection:IP67 (sensor head) / IP65 (housing) / III (SELV) or PELV
Schmidt SS 20.260 Flow Sensor
Medium:Air or nitrogen, other gases upon requeste
Measuring range : 0 ... 60 m/s
Output : 0 ... 10 V / 4 ... 20 mA
Operating temperature : -20 ... +120°C
Accuracy : ±(5% of measured value + [0.4 % of final value; min. 0.02 m/s])
Operating pressure : Atmospheric (700 … 1.300 hPa)
Ingress protection/protection class:IP 65 / III or PELV
eyc-tech FDM06-I Venturi Thermal Mass Flow Meter
Features : Utilizes a unique Venturi tube structure, the Inline type air flow sensor designed for compressed air system
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : 0 ... 4000 m³/h
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : ±1.5% F.S.
IP rating : IP65
eyc-tech THS88ECO Industrial Dew Point Transmitter
Features : OEM Economic-Type Bulk Products
Sensor type : Capacitive humidity sensor & Pt100
Dew point scaling range : -80 ... +20 dp°C
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±2.5 dp°C
IP rating : IP65 (Probe : IP20)
eyc-tech THS88MAX Industrial Dew Point Transmitter
Features : Suitable for compressed dry air systems and industrial drying systems.
Sensor type : Capacitive humidity sensor & Pt100
Dew point scaling range : -80 ... +20 dp°C
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±1 ... ±2 dp°C
IP rating : IP65 (Probe : IP20)
eyc-tech THS90Q Industrial Ultra-Low Dew Point Transmitter
Features : Ultra-Low Dew Point Measurement, Fast Response and Low-Moisture Detection
Sensor type : QCM
Dew point scaling range : -100 ... 0 dp°C
Output : 4 ... 20 mA + RS-485 (Standard) / 0 ... 10 V + RS-485 (on request)
Accuracy : -80 ... -20 dp°C: ±2 dp°C / -100 ... -80 dp°C: ±3 dp°C
IP rating : IP54 (Housing) / IP20 (Probe)
RH Systems 973 Dew Point Mirror
Measuring range:Frost/Dew Point -50…+20°C / %RH 5…100% / Temperature -50…+150°C
Accuracy:Frost/Dew point ±0.1°C / Temperature ±0.07°C
Reproducibility:Frost/Dew Point ± 0.05°C / Temperature ± 0.05°C
Operation temperature: -10…+40°C
Digital I/O: RS-232
RH Systems 473 Dew Point Mirror
Measuring Ranges:Frost/Dew Point -20 … 70°C / Relative humidity 2 … 100 %RH / Temperature -50 … 100 °C
Digital I/O:RS-232
Analog outputs:Two user programmable, -10… +10 V & 4…20 mA
Accuracy:Frost/Dew point ≤ ± 0.1 … 0.15 °C / Temperature ≤±0.07 °C
RH Systems 373 Dew Point Mirror
Measuring Ranges:Frost/Dew Point -95 … +95 °C
Digital I/O:RS-232
Analog outputs:Two analog outputs, user programmable, -10 … +10V & 4 … 20mA
Accuracy:±0.1°C Frost/Dew point