Explosion proof

Schmidt SS 20.500 Flow Sensors

Medium :Air / nitrogen or other gases on request
Measuring range : 0 ... 50 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : -40 ... +85°C
Accuracy:±(3% of measured value + [0.4% of end of measuring range; min. 0.02 m/s])
Operating pressure : Compact sensor 10 bar (overpressure) / Remote sensor atmospheric (700 hPa … 1,300 hPa)
Type / class of protection:IP67 (sensor head) / IP65 (housing) / III (SELV) or PELV

Galltec KC.Ex / GC.Ex Humidity and Temperature Sensor with ATEX Certificate

Measuring element:Pt 100 class B
Measuring range:-20...+80°C / 0 … 100%RH
Output:4...20 mA
Accuracy at 23°C:Humidity ±2%rh, other ranges ±0.3 K / Temperature ±0.2 K, other ranges ±0.3 K
Operating temperature:-40...+80°C
Degree of protection:IP65

Dinel ULM-53 Ultrasonic Level Meters

Measuring range:0.1 ... 20 m
Output:4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy:0.3% / 0.2% / 0.15%
Supply voltage:DC 18 ... 36 V / DC 18 ... 30 V
Ambient temperature range:-30 ... +70°C
Protection class:IP67 / IP68

Dinel CPS-24 Capacitive Proximity Switch

Output : NPN / PNP / NAMUR
Supply voltage : DC 7...36 V
Current supply (state OFF / ON) : 3/6 mA
Switching current (NPN, PNP output) : 200 mA
Ambient temperature range:-20 ... +70°C
Protection class:IP67

Dinel ULM-70 Ultrasonic Level Meters

Measuring range:0.15 ... 20 m
Output:4 ... 20 mA / HART® / RS-485 with protocol Modbus RTU
Accuracy:0.15%
Supply voltage:DC 18 ... 36 V / DC 18 ... 30 V
Ambient temperature range:-30 ... +70°C
Protection class:IP67

Dinel DLS-27 Capacitive Level Sensors

Output : NPN / PNP / NAMUR
Supply voltage : 7 ... 36 V DC / 7 ... 33 V DC
Current supply (state OFF / ON) : 3 / 10 mA
Max. switching current (NPN, PNP) : 200 mA
Temperature and pressure resistivity:-40°C ... +300°C / 0.1 ... 3 MPa
Protection class:IP67

GREISINGER Finest manometer GMH 3161-07

FLUIDWELL E110 Explosion proof - Flow rate Indicator / Totalizer

Input : Pulse signal (coil, NAMUR, NPN/PNP, reed-switch, active pulse)
Output : 4 ... 20 mA analog output, scaled pulse output
Communication : RS-232 / RS-485 (Modbus) or USB
Power supply : Long-life lithium battery / loop-powered 4 ... 20 mA / 9 ... 27 V DC
Ambient temperature : -40°C ... +70°C (aluminum) / -40°C ... +67°C (stainless steel)
Explosion proof : ATEX, IECEx, CSA C-US (gas and dust)

FLUIDWELL F126-EG Intrinsically Safe - Flow Computer

Input : Flowmeter / Temperature / Pressure
Output : Pulse / Alarm / Analog
Temperature : 100°C to +200°C
Power Supply : Long life Lithium battery / 4 – 20mA Loop-powered / 8 – 24V AC/DC / 115 – 230V AC / Basic: 8 - 30V DC
Explosion Proof : ATEX/IECEx

Rheonik RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

MEASUREMENTS:Mass Flow / Volumetric Flow / Density / Temperature
FUNCTIONS:Batch / Filling Control / Standard Volume Gas Flow / Assurance Factor® / API std. Volume, Net Oil / Tamperproof Lock Switch
OUTPUTS:2 x Analog / 2 x Frequency / Pulse / 2 x Digital Status
INPUTS:2 x Digital / 1 x Analog
INTERFACES:PC USB / RHECom / RS-485 / Modbus RTU / HART over analog
APPROVALS:ATEX / IEC Ex / CSA

Rheonik RHM20 Industrial Coriolis Mass Flow Meter

TYPICAL APPLICATION RANGE:2.25 up to 300 kg/min
MAX. PRESSURE:799 bar / 11588 psi
TEMPERATURE:-196 up to +400°C
ACCURACY:0.1% of rate
MATERIALS:316Ti / 904L / Alloy C22 / Tantalum / more on request
PROCESS CONNECTIONS:1″ up to 3″

eyc-tech THM14EX EX-Series Temp. and Humidity Transmitter

Features : Designed for industrial application. Explosion proof.
Sensor type : Capacitive Humidity Sensor & Pt 100
Measuring range : Temperature -20 ... +80°C / Humidity 0 ... 100%RH
Output : 4 ... 20 mA
Accuracy : Temperature ±0.3°C / Humidity ±2%RH
IP rating : IP66