eyc-tech
eyc-tech FDM06-P Average Flow Thermal Mass Transmitter
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.5 ... 60 m/s:±(1.5% of mv + 0.8 m/s)
IP rating : IP65
Turndown ratio : 100 : 1
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.5 ... 60 m/s:±(1.5% of mv + 0.8 m/s)
IP rating : IP65
eyc-tech FUM06 Ultrasonic Flowmeter
Features : Non-intrusive and high-precision measurement, suitable for various fluids and pipe sizes.
Sensor type : Ultrasonic time difference
Turndown ratio : 100 : 1
Measuring range : 0.1 ... 10 m/s
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±1% F.S.
IP rating : IP65
Sensor type : Ultrasonic time difference
Turndown ratio : 100 : 1
Measuring range : 0.1 ... 10 m/s
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±1% F.S.
IP rating : IP65
eyc-tech PMM06-D Differential Pressure Transmitter
Feature : Utilizing hot-wire sensing technology, high sensitivity for detecting minute differential pressure
Measuring element : Thermal mass type
Measuring range : ±10, ±25, ±50, ±100 Pa
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : ±(1% F.S. + 0.1 Pa)
IP rating : IP65
Measuring element : Thermal mass type
Measuring range : ±10, ±25, ±50, ±100 Pa
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : ±(1% F.S. + 0.1 Pa)
IP rating : IP65
eyc-tech AFMP Average Flow Measuring Tube (Pitot tube)
Features : Multi-point averaging. Suitable for large pipes. Resistant to high temperature and corrosion.
Operating pressure : Standard type : Max. 10 bar / High-temp. type : Max. 4 bar
Operating temperature : Standard type : Max. 200°C / High-temp. type : Max. 600°C
Length : 2" ... 40"(50 ... 1000 mm)
Operating pressure : Standard type : Max. 10 bar / High-temp. type : Max. 4 bar
Operating temperature : Standard type : Max. 200°C / High-temp. type : Max. 600°C
Length : 2" ... 40"(50 ... 1000 mm)
eyc-tech FDM06-L Bi-directional Low Air Flow Thermal Mass Transmitter (Duct / Remote type)
Features : Bi-directional transmitter for tight-space insertion
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : ±(0.00 ... 1 m/s), ±(0.00 ... 2 m/s), ±(0.00 ... 10 m/s), ±(0.00 ... 30.00 m/s)
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.05 ... 1.00 m/s:±(1% of mv+0.05 m/s), 0.05 ... 2.00 m/s:±(1% of mv+0.1 m/s), 0.1 ... 10.00m/s:±(1% of mv+0.2 m/s), 0.5 ... 30.00m/s:±(1% of mv+0.5 m/s)
IP rating : IP65
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : ±(0.00 ... 1 m/s), ±(0.00 ... 2 m/s), ±(0.00 ... 10 m/s), ±(0.00 ... 30.00 m/s)
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.05 ... 1.00 m/s:±(1% of mv+0.05 m/s), 0.05 ... 2.00 m/s:±(1% of mv+0.1 m/s), 0.1 ... 10.00m/s:±(1% of mv+0.2 m/s), 0.5 ... 30.00m/s:±(1% of mv+0.5 m/s)
IP rating : IP65
eyc-tech FDM06-L Bi-directional Low Air Flow Thermal Mass Transmitter (Laminar flow / Overflow type)
Features : Ultra-low flow detection with reverse flow alert
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : ±(0.00 ... 2 m/s)
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.05 ... 2.00 m/s:±(1% of mv+0.1 m/s)
IP rating : IP65
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : ±(0.00 ... 2 m/s)
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.05 ... 2.00 m/s:±(1% of mv+0.1 m/s)
IP rating : IP65
eyc-tech FDM06-I Venturi Thermal Mass Flow Meter
Features : Utilizes a unique Venturi tube structure, the Inline type air flow sensor designed for compressed air system
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : 0 ... 4000 m³/h
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : ±1.5% F.S.
IP rating : IP65
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Measuring range : 0 ... 4000 m³/h
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : ±1.5% F.S.
IP rating : IP65
eyc-tech THS88MAX Industrial Dew Point Transmitter
Features : Suitable for compressed dry air systems and industrial drying systems.
Sensor type : Capacitive humidity sensor & Pt100
Dew point scaling range : -80 ... +20 dp°C
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±1 ... ±2 dp°C
IP rating : IP65 (Probe : IP20)
Sensor type : Capacitive humidity sensor & Pt100
Dew point scaling range : -80 ... +20 dp°C
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±1 ... ±2 dp°C
IP rating : IP65 (Probe : IP20)
eyc-tech FDM08 Venturi Inline Type Air Flow Transmitter
Features : Venturi inline type air flow measurement, a wide range of applications
Sensor type : Differential pressure sensor
Air flow measuring range : Reference airflow range table based on environmental conditions
Output signal: 4 ... 20 mA
Accuracy : ±2%
IP rating : IP65 (Housing)
Sensor type : Differential pressure sensor
Air flow measuring range : Reference airflow range table based on environmental conditions
Output signal: 4 ... 20 mA
Accuracy : ±2%
IP rating : IP65 (Housing)
eyc-tech THM88MAX Industrial dew point transmitter with display
Features:Suitable for compressed dry air system and industrial drying system. Integrated LED display. Faster response to low dew point.
Sensor type:Capacitive humidity sensor & Pt100
Operating range of dew point : -40 ... +20 dp°C
Output:4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy:±1 ... ±1.5 dp°C
IP rating:IP65(Housing) / IP20(Probe)
Sensor type:Capacitive humidity sensor & Pt100
Operating range of dew point : -40 ... +20 dp°C
Output:4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy:±1 ... ±1.5 dp°C
IP rating:IP65(Housing) / IP20(Probe)
eyc-tech FTC05 Hot Wire Thermal Flow Switch
Features:Suitable for oil, water and liquid flow monitoring. Also work as level detector.
Sensor type:Resistance Temperature Detector (RTD)
Measuring range:1 ... 200 cm/s(Water) / 3 ... 300 cm/s(Oil) / 6 ... 20 m/s(Gas)
Output:PNP / NPN / Relay
IP rating:IP65(Option IP67)
Sensor type:Resistance Temperature Detector (RTD)
Measuring range:1 ... 200 cm/s(Water) / 3 ... 300 cm/s(Oil) / 6 ... 20 m/s(Gas)
Output:PNP / NPN / Relay
IP rating:IP65(Option IP67)
eyc-tech DPM05 Flow Computer
Display readout : Instantaneous flow : 5-digit / Cumulative flow : 8-digit
Input : Flow / Pressure / Temperature
Output : Current / Relay / RS-485
Accuracy : ±0.2% F.S. ±1 digit
IP rating : IP54 (Front panel)
Input : Flow / Pressure / Temperature
Output : Current / Relay / RS-485
Accuracy : ±0.2% F.S. ±1 digit
IP rating : IP54 (Front panel)