Explosion proof

Huba 525 industrial pressure transmitter

Medium : Liquids and gases
Pressure range : 0 ... 0.05 – 0.6 bar
Output : 0 ... 5 V, 0 ... 10 V, 4 ... 20 mA, ratiom. 10 ... 90%
Accuracy : ± 0.35% fs

HUBA 520 Relative Pressure Transmitter

Medium : Liquids, gases and refrigerants (incl. ammonia)
Pressure range : -1 ... 9 bar / 0 ... 2.5 – 1000 bar
Output : 0 ... 5 V, 1 ... 6 V, 0 ... 10 V, ratiom. 10 ... 90% , 4 ... 20 mA
Accuracy : typ. <0.3% FS

Huba 681 Level transmitter

Measuring range : 0 ... 0.1 – 25 bar
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Media : Diesel oil / Fuel oil / Kerosene / Salt water / Brackish water / Drinking water / Potable / Lake water / River water / Benzene / Chlorinated water
Cable : PUR / PE / Teflon

EGE SZAb 400 Flow Sensors

Output:Relay/change-over
Supply voltage:AC 230 V ±10%
Ex marking-GAS:II(1)GD [Ex ia] IIC
Ex marking-Dust:II(1)GD [Ex ia] IIIC

PR 9106B HART transparent repeater

• 24 VDC supply via power rail or connectors
• Active and passive mA input
• Active or passive output via the same two terminals
• Splitter function - 1 in and 2 out
• SIL3 Full Assessment and certified acc. to IEC 61508

PR 5333D 2-wire Programmable Transmitter

Input:RTD / Ohm
Ouput: 4...20 mA
Accuracy:Better than 0.1% of sel. range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal): IP68 / IP00

PR 9116B Universal Converter

Input:RTD / TC / Ohm / Potentiometer / mA / V
Output:Active / passive mA output and relay
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20

PR 5437D 2-wire HART 7 temperature transmitter

Input:RTD / TC / Potentiometer / Ohm / mV
Output:3.8...20.5 / 20.5...3.8 mA
Operating temperature:-50°C ... +85°C
Accuracy:< ±0.1% of span
Protection degree (encl./terminal):IP68 / IP00

PR 5335D 2-wire transmitter with HART protocol

Input:RTD / TC / Ohm / mV
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00

PR 5202B Pulse Isolator

Sensor types:NAMUR according to EN 60947-5-6 / mechanical contact
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20

Schmidt SS 23.700-EX Flow Sensor

Medium to be measured: Standard: air or nitrogen / Optional: biogas, methane, natural gas, argon, COs, special gases and mixtures and others (on request)
Measuring range wN: 0 ... 220 m/s
Output: Analog / Pulse
Operating temperature: -20 ... +120 °C
Operating overpressure (max.): 16 bar
Type of protection: IP66 (housing), IP67 (sensor probe) / II 3G Ex ec ic IIC T4 Gc / II 3D Ex ic tc IIIC 135°C Dc

Schmidt SS 23.400 Flow Sensor

Medium :Clean air / Nitrogen / Additional gases on request
Measuring range : 0 ... 20 m/s
Output :0 … 10 V / 4 ... 20 mA(for option ATEX not for sensor length 130 mm)
Operating temperature : 0 ... +60°C
Operating pressure : Atmospheric (700 … 1,300 hPa)
Protection type / protection class:IP 66/III (SELV) or PELV (EN 50178)

Schmidt SS 20.500 Flow Sensors

Medium :Air / nitrogen or other gases on request
Measuring range : 0 ... 50 m/s
Output :0 … 10 V / 4 ... 20 mA
Operating temperature : -40 ... +85°C
Accuracy:±(3% of measured value + [0.4% of end of measuring range; min. 0.02 m/s])
Operating pressure : Compact sensor 10 bar (overpressure) / Remote sensor atmospheric (700 hPa … 1,300 hPa)
Type / class of protection:IP67 (sensor head) / IP65 (housing) / III (SELV) or PELV

Galltec KC.Ex / GC.Ex Humidity and Temperature Sensor with ATEX Certificate

Measuring element:Pt 100 class B
Measuring range:-20...+80°C / 0 … 100%RH
Output:4...20 mA
Accuracy at 23°C:Humidity ±2%rh, other ranges ±0.3 K / Temperature ±0.2 K, other ranges ±0.3 K
Operating temperature:-40...+80°C
Degree of protection:IP65

Dinel ULM-53 Ultrasonic Level Meters

Measuring range:0.1 ... 20 m
Output:4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy:0.3% / 0.2% / 0.15%
Supply voltage:DC 18 ... 36 V / DC 18 ... 30 V
Ambient temperature range:-30 ... +70°C
Protection class:IP67 / IP68

Dinel CPS-24 Capacitive Proximity Switch

Output : NPN / PNP / NAMUR
Supply voltage : DC 7...36 V
Current supply (state OFF / ON) : 3/6 mA
Switching current (NPN, PNP output) : 200 mA
Ambient temperature range:-20 ... +70°C
Protection class:IP67

Dinel ULM-70 Ultrasonic Level Meters

Measuring range:0.15 ... 20 m
Output:4 ... 20 mA / HART® / RS-485 with protocol Modbus RTU
Accuracy:0.15%
Supply voltage:DC 18 ... 36 V / DC 18 ... 30 V
Ambient temperature range:-30 ... +70°C
Protection class:IP67

Dinel DLS-27 Capacitive Level Sensors

Output : NPN / PNP / NAMUR
Supply voltage : 7 ... 36 V DC / 7 ... 33 V DC
Current supply (state OFF / ON) : 3 / 10 mA
Max. switching current (NPN, PNP) : 200 mA
Temperature and pressure resistivity:-40°C ... +300°C / 0.1 ... 3 MPa
Protection class:IP67

FLUIDWELL E110 Explosion proof - Flow rate Indicator / Totalizer

Input : Pulse signal (coil, NAMUR, NPN/PNP, reed-switch, active pulse)
Output : 4 ... 20 mA analog output, scaled pulse output
Communication : RS-232 / RS-485 (Modbus) or USB
Power supply : Long-life lithium battery / loop-powered 4 ... 20 mA / 9 ... 27 V DC
Ambient temperature : -40°C ... +70°C (aluminum) / -40°C ... +67°C (stainless steel)
Explosion proof : ATEX, IECEx, CSA C-US (gas and dust)

Rheonik RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

MEASUREMENTS:Mass Flow / Volumetric Flow / Density / Temperature
FUNCTIONS:Batch / Filling Control / Standard Volume Gas Flow / Assurance Factor® / API std. Volume, Net Oil / Tamperproof Lock Switch
OUTPUTS:2 x Analog / 2 x Frequency / Pulse / 2 x Digital Status
INPUTS:2 x Digital / 1 x Analog
INTERFACES:PC USB / RHECom / RS-485 / Modbus RTU / HART over analog
APPROVALS:ATEX / IEC Ex / CSA

Rheonik RHM20 Industrial Coriolis Mass Flow Meter

TYPICAL APPLICATION RANGE:2.25 up to 300 kg/min
MAX. PRESSURE:799 bar / 11588 psi
TEMPERATURE:-196 up to +400°C
ACCURACY:0.1% of rate
MATERIALS:316Ti / 904L / Alloy C22 / Tantalum / more on request
PROCESS CONNECTIONS:1″ up to 3″

eyc-tech THM14EX EX-Series Temp. and Humidity Transmitter

Features : Designed for industrial application. Explosion proof.
Sensor type : Capacitive Humidity Sensor & Pt 100
Measuring range : Temperature -20 ... +80°C / Humidity 0 ... 100%RH
Output : 4 ... 20 mA
Accuracy : Temperature ±0.3°C / Humidity ±2%RH
IP rating : IP66