Huba 681 Level transmitter

Huba 681
  • Huba 681 Level transmitter
Features
The pressure transmitters of Type 681 with piezoresistive measuring elements have compensated, calibrated, and amplified sensor signals, which are provided as standardized voltage or current outputs. In the version as a submersible probe with saltwater- and oil-resistant connection cable, they are particularly suitable for level measurement of aggressive liquids. For ambient pressure compensation, a tube is routed through the cable. All metal parts made of stainless steel are hermetically welded.

•Mechanically protected membrane through special head design
•100 % sealed against medium, as fully welded
•Better stabilization of the sensor in turbulent media through additional weight (option)
•High overload safety due to chemically etched chip membrane and special design of the glass feedthrough
•Compact design in SMD technology increases operational safety during shock and vibrations
Specification
Product feature
Pressure measuring range
0 ... 0.1 – 25 bar
Pressure measuring range
optionally available (Absolute)
Field of application
Permissible overload
3x Pressure range
Bursting pressure
<200 bar
Media
Diesel oil / Fuel oil / Kerosene / Salt water / Brackish water / Drinking water / Potable / Lake water / River water / Benzene / Chlorinated water
Medium temperature
-5 ... 80 °C
Material
Housing
Stainless steel 1.4435 (316L); Titanium
Sealing material
FPM
Cables
Teflon / PUR / PE
Electrical data
Supply voltage 3-wire
13 ... 30 VDC
Current consumption 3-wire
0 ... 10 V
Permissible load 3-wire
>10 kOhm
Supply voltage 2-wire
9 ... 33 VDC
Current consumption 2-wire
4 ... 20 mA
Permissible load 2-wire
< (supply voltage - 9V)/0.02 A (max.)
Supply voltage 2-wire (Ex)
9 ... 28 VDC
Current consumption 2-wire (Ex)
4 ... 20 mA
Permissible load 2-wire (Ex)
< (supply voltage - 9V)/0.02 A (max.)
Cable length
various lengths
Explosion protection
ATEX Gas
II 1G Ex ia IIB/IIC T3 ... T6
ATEX Dust
II 1D Ex iaD 20 IP6x T145 ... T70 ÀC
Standards Gas
EN 60079-0 / EN 60079-11
Standards Dust
EN 61241-0 / EN 61241-11
Temperature class
T6; T4
Approval
Interference emission
EN 55022
Shock
EN 60068-2-27
Vibration
EN 60068-2-6
Interference resistant
EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6
Download
Note : Design and specifications are subject to change without notice.
Note : Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.