Flow transmitter

View:

EGE SKM 420 GR/GA Flow Sensors

Output:Relay / PNP / 4 … 20 mA
Supply voltage :DC 24 V ±20%
Ambient temperature:-20 … +60℃
IP rating:terminal: IP 20 / housing: IP 40

EGE SZAb 400 Flow Sensors

Output:Relay/change-over
Supply voltage:AC 230 V ±10%

Ex marking:
GAS:II(1)GD [Ex ia] IIC
Dust:II(1)GD [Ex ia] IIIC

SYSTEC deltawave C-F Clamp-on Ultrasonic Flowmeter

SYSTEC deltawaveVer2 Multipath Ultrasonic Flowmeter

Rheonik RHE16 Compact Multifunction Coriolis Flow Meter Transmitter

MEASUREMENTS:Mass Flow / Density / Temperature
FUNCTIONS:Volume Flow / Advanced Diagnostics / Flow Data Analysis
OUTPUTS:1 Analog / 2 Frequency / 2 Pulse / 2 Digital Status
INTERFACES:RS 485 / MODBUS

Rheonik RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

MEASUREMENTS:Mass Flow / Volumetric Flow / Density / Temperature
FUNCTIONS:Batch / Filling Control / Standard Volume Gas Flow / Assurance Factor® / API std. Volume, Net Oil / Tamperproof Lock Switch
OUTPUTS:2 x Analog / 2 x Frequency / Pulse / 2 x Digital Status
INPUTS:2 x Digital / 1 x Analog
INTERFACES:PC USB / RHECom / RS-485 / Modbus RTU / HART over analog
APPROVALS:ATEX / IEC Ex / CSA

Rheonik RHM08 Versatile Coriolis Mass Flow Meter

TYPICAL APPLICATION RANGE:0.3 up to 50 kg/min
MAX. PRESSURE:1254 bar / 18057 psi
TEMPERATURE:-196 up to +400°C
ACCURACY:0.1% of rate
MATERIALS:316Ti / Alloy C22 / HP160 / Tantalum / more on request
PROCESS CONNECTIONS:1/2″ up to 2″

Rheonik RHM15 Process Sized Coriolis Mass Flow Meter

TYPICAL APPLICATION RANGE:1 up to 200 kg/min
MAX. PRESSURE:882 bar / 12792 psi
TEMPERATURE:-196 up to +400°C
ACCURACY:0.1% of rate
MATERIAL:316Ti / Alloy C22 / SuperDuplex / Tantalum / more on request
PROCESS CONNECTIONS:3/4″ up to 2″

HONSBERG RRI Flow transmitter

Sensor:inductive
Mechanical Connection:female thread G 3/8, G 1 / male thread G 3/8 A, G 1 A / hose nozzle Ø11, Ø30
Pressure resistance:PN 16 bar
Medium temperature:0..60 °C
Ingress protection:IP 67

HONSBERG RT Flow transmitter

Sensor:biased Hall sensor
Nominal width:DN 15..50
Process connection:male thread G 1/2 A...G 2 A
Metering ranges:1.8..1133 l/min
Measurement accuracy:±1 % of full scale value
Medium temperature:-20..+85 °C / optionally -20..+150 °C (for 8 bar min.)
Ambient temperature:-20..+70 °C

HONSBERG Flow Transmitter VHZ

FLUIDWELL F126-EG Intrinsically Safe - Flow Computer

Input:Flowmeter / Temperature / Pressure
Output:Pulse / Analog
Ambient temperature:-40°C ... +80°C
Power Supply:Long life Lithium battery / 4 – 20mA Loop-powered / 8 – 24V AC/DC / 115 – 230V AC / Basic: 8 - 30V DC
Explosion Proof:ATEX