| Pressure range | |
| Relative | 0 ... 0.05 – 0.6 bar |
| Operating conditions | |
| Medium | Liquids; Gases |
| Medium temperature |
FPM -15 ... +85°C EPDM -25 ... +85°C NBR -20 ... +85°C |
| Ambient temperature | -25 ... +85°C |
| Storage temperature | -40 ... +85°C |
| Tolerable overload / rupture pressure | 2 bar |
| Tolerable negative pressure | -0.3 bar |
| Materials | |
| Plug accommodation | Polyarylamide 50% GF UL 94 V-0 |
| Pressure connection | Stainless steel 1.4404 / AISI 316L |
| Measuring element | Ceramic Al₂O₃ (99.6%) |
| Sealing material | FPM, EPDM, NBR |
| Electrical overview | |
| 2 wire | 4 ... 20 mA / 10 ... 30 VDC |
| 3 wire |
0 ... 5 V / 7 ... 33 VDC 0 ... 10 V / 12 ... 33 VDC Ratiometric 10 ... 90% / 5 VDC ±10% |
| Insulation voltage | 500 VDC |
| Current consumption |
< 23 mA (4 ... 20 mA) < 5 mA (voltage output) |
| Dynamic response | |
| Start-up time | < 200 ms |
| Response time | < 150 ms |
| Load cycle | < 100 Hz |
| Accuracy | |
| Characteristic line (25°C) |
± 0.35 % fs (fs < 100 mbar ±0.7 % fs) |
| Resolution | < 0.1 % fs |
| Long term stability | ± 0.25 % fs |
| Thermal characteristics | ± 0.07 % fs / 10K |
| Mounting error | |
| Horizontal mounting | +0.1 mbar |
| Vertical mounting (pressure port upward) | +0.2 mbar |
| Approvals | |
| EMC | CE acc. EN 61326-2-3 |
| Shock | IEC 68-2-27 50 g |
| Vibration | IEC 68-2-6 20 g |
| UL | ANSI/UL 61010-1 E325110 |
| Explosion protection (4 ... 20 mA) |
Ex II ½ G Ex ia IIC T4 Ga/Gb Ex II ½ D Ex ia IIIC T120°C Da/Db |
| Weight | ~ 120 g |