Input |
|
Sensor |
Hot wire mass flow transmitter |
Measuring range |
0 ... 20 m/s |
Min. measuring range |
0.2 m/s |
Installation angle effect |
(When the installation angle<10°) ±3%F.S.(Nonlinear error, Hysteresis) |
Output |
|
Output signal |
4 ... 20 mA / DC 0 ... 10 V |
Signal connection |
3-Wire |
Load resistance |
Current output : ≦500 Ω |
Response time |
t90≦5 sec(τ : 90%) |
Accuracy |
|
Accuracy |
±3%F.S. |
Temp. influence |
0.3% / °C |
Environment |
|
Medium & Temp. |
Air, 0 ... 50°C |
Body operating Temp. |
0 ... 50°C |
Body operating Humid. |
95%RH(Non-condensing |
Storage Temp. |
-20 ... +60°C |
Electrical |
|
Power supply |
DC 24 V & AC 12 ... 30 V |
Current consumption |
DC 24 V : 120 mA / AC 12 V : 350 mA / AC 24 V : 180 mA |
Overvoltage protection |
DC : <40 V;AC : <40 V |
Electrical connection |
Terminal |
Installation |
|
Fixed seat |
Duct type / Flange type |
Protection |
|
IP rating |
IP54 |
Electrical protection |
■ Reverse polarity |
Certification |
|
Certification |
CE |
Material |
|
Housing / Probe |
PC fire-proof(UL94V-2) / PC fire-proof |
Probe head / Wire |
PC |
Weight |
~150 g |