HONSBERG RT Flow transmitter

HONSBERG-RT Flow transmitter
  • HONSBERG RT Flow transmitter
Features
  • High precision
  • No magnetic components in the flow space
  • High pressure resistance
A turbine acts as the primary sensor; its rotational speed is proportional to the flow rate. The rotational speed is detected by means of a biased Hall sensors, i.e. there are no magnets in the flow space.
Specification
Sensor:biased Hall sensor
Nominal width:DN 15..50
Process connection:male thread G 1/2 A...G 2 A
Metering ranges:1.8..1133 l/min for details, see table "Ranges"
Measurement accuracy:±1 % of full scale value in the specified metering range, including linearity and repeatability
Medium temperature:-20..+85 °C / optionally -20..+150 °C (for 8 bar min.)
Ambient temperature:-20..+70 °C
Storage temperature:-20..+80 °C
Materials medium-contact:Housing stainless steel 315 / Turbine stainless steel 430 / Bearing tungsten carbide
Material electronics housing:CW614N nickelled
Max. particle size:0.5 mm
Pressure loss:0.3 bar at Qmax.
Pressure resistance:PN 250 bar
Supply voltage:10..30 V DC
Signal output:transistor output "push-pull" (resistant to short circuits and polarity reversal)
Iout = 100 mA max.
Current consumption:20 mA without load
Max. load current:100 mA
Electrical connection:for round plug connector M12x1, 4-pole
Download
Note : Design and specifications are subject to change without notice.
Note : Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.