Signal meter
PR 4116 Universal Transmitter
Input:RTD / TC / Ohm / potentiometer / mA / V
Output:current, voltage and 2 relays
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C to +60°C
Relative humidity:< 95% RH (non-cond.)
Protection degree:IP20
Output:current, voltage and 2 relays
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C to +60°C
Relative humidity:< 95% RH (non-cond.)
Protection degree:IP20
PR 5104B Ex Repeater / Power Supply
Input:Voltage / Current
Output:Voltage / Current
Accuracy : Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20
Output:Voltage / Current
Accuracy : Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20
PR 4510 Display / programming front
Programming display for all past and present 4000 / 9000 series devices, 3000 series devices where applicable, and all versions of ConfigMate 4590
Monitor process value and status from the built-in display
Scrolling help text in 7 languages
Monitor process value and status from the built-in display
Scrolling help text in 7 languages
PR 5335D 2-wire transmitter with HART protocol
Input:RTD / TC / Ohm / mV
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00
PR 5202B Pulse Isolator
Sensor types:NAMUR according to EN 60947-5-6 / mechanical contact
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20
PR 3108 Isolated repeater/splitter
Current input:Measurement range 0...23 mA
Current output:Signal range 0...23 mA
Accuracy:Better than 0.05%
Operating temperature:-25°C ... +70°C
Protection degree:IP20
Current output:Signal range 0...23 mA
Accuracy:Better than 0.05%
Operating temperature:-25°C ... +70°C
Protection degree:IP20
PR 9116B Universal Converter
Input:RTD / TC / Ohm / Potentiometer / mA / V
Output:Active / passive mA output and relay
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20
Output:Active / passive mA output and relay
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20
PR 6334A 2-wire Programmable Transmitter
Input:TC
Output:4…20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree:IP20
Output:4…20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree:IP20
Dinel NSSU_NDSU_NLCU SERIES Intrinsically Safe Supply Units
Nominal supply voltage: Version 230 V: 30 ... 230 V AC/DC (+10%) 50 ÷ 60 Hz / Version 24 V: 10 ... 30 V AC (+10%) 50 ÷ 60 Hz; 10 ... 40 V DC (+10%)
Nominal power demand (AC / DC): 4 VA / 4 W
Output open – Circuit voltage: 9.2 V DC
Output current – Treshold: 1.55 mA (± 0.1 mA)
Ambient temperature: -20°C ... +60°C
Protection: IP20
Nominal power demand (AC / DC): 4 VA / 4 W
Output open – Circuit voltage: 9.2 V DC
Output current – Treshold: 1.55 mA (± 0.1 mA)
Ambient temperature: -20°C ... +60°C
Protection: IP20