THS17-MD Temperature and Humidity Transmitter|Short-Probe Design, Data Center Preferred
THS17-MD
Temperature and Humidity Transmitter|Short-Probe Design, Data Center Preferred
In data centers, the density of server racks increases year by year, and the arrangement of cables and airflow-guiding structures becomes more complex, making the space between cold and hot aisles increasingly limited. When installing temperature and humidity monitoring equipment in such environments, the probe length, appearance, and installation depth directly affect airflow stability and overall deployment efficiency. This product adopts a streamlined probe proportion as its core design, allowing installation without disturbing the supply and return airflow paths, while providing stable and reliable environmental measurement.
Streamlined
Probe Configuration for Narrow Airflow Channels
Air inlets, exhaust areas, equipment-side
ducts, and cable-dense locations often include brackets and baffles, causing
standard probes to easily disrupt existing airflow patterns due to excessive
insertion depth. This product adopts a shortened probe proportion suitable for
confined spaces, allowing the sensing position to be closer to the actual
airflow layer while avoiding additional airflow resistance. Its more compact
exterior makes angle and depth adjustments more intuitive, improving deployment
efficiency in densely packed equipment areas.
Fast Response and Stable Output to Support Dynamic Cooling Environments
High computing loads can cause significant
short-term fluctuations in the temperature and humidity of cold and hot aisles.
If the response is not fast enough, cooling equipment will struggle to adjust
in time. This product can quickly provide stable data when environmental
changes occur, allowing management platforms to anticipate heat accumulation
and cooling mode adjustments. This characteristic effectively reduces the risks
of overheating, condensation, and static electricity, making it particularly suitable
for high-density servers and AI/HPC operating scenarios.
RS-485 Digital Communication to Enhance Monitoring System Integration Efficiency
Large-scale data centers often require
monitoring across multiple rows of racks or even separate rooms, making signal
consistency and wiring quality keys to system integration. This product uses
RS-485 digital output, offering strong anti-interference capability and
long-distance transmission performance, ensuring measurement data can be
reliably returned to BMS, DCIM, or SCADA platforms. It also enhances system
scalability, allowing new monitoring nodes to be easily integrated into the
existing architecture.
Suitable for Measurement Needs in Multiple Critical Cooling Zones
The streamlined probe structure and robust
metal construction enable this product to adapt to various critical monitoring
locations, including cold aisle fronts, hot aisle rears, narrow rack-side
areas, underfloor supply-air plenum boxes, air-conditioning supply and return
points, and high-heat equipment surroundings. Its form factor does not
interfere with airflow design yet can provide stable measurement in densely
populated equipment zones, enhancing the precision of overall environmental
control.
Feature : Probe type. Easy to install. Cost effective.
Sensor type : MEMS
Measuring range : 0°C ... +50°C / 0 ... +100%RH (Non-condensing)
Output : RS-485
Accuracy : ±0.1°C / ±1.0%RH
IP rating : IP24 ( Sensor ) / IP 65 ( Body )