PR electronics
PR 9106B HART transparent repeater
• 24 VDC supply via power rail or connectors
• Active and passive mA input
• Active or passive output via the same two terminals
• Splitter function - 1 in and 2 out
• SIL3 Full Assessment and certified acc. to IEC 61508
• Active and passive mA input
• Active or passive output via the same two terminals
• Splitter function - 1 in and 2 out
• SIL3 Full Assessment and certified acc. to IEC 61508
PR 3105 Isolated converter
• Isolation and conversion of standard DC signals
• Response time < 7 ms
• DIP switch configuration
• Low cost
• Slimline housing of 6.1 mm
• Response time < 7 ms
• DIP switch configuration
• Low cost
• Slimline housing of 6.1 mm
PR 3333 Pt100 converter, loop-powered
• Excellent accuracy, better than 0.1% of span
• Excellent EMC performance and 50/60 Hz noise suppression
• Selectable < 30 ms / 300 ms response time
• Pre-calibrated temperature ranges selectable via DIP switches
• Slimline 6.1 mm housing
• Excellent EMC performance and 50/60 Hz noise suppression
• Selectable < 30 ms / 300 ms response time
• Pre-calibrated temperature ranges selectable via DIP switches
• Slimline 6.1 mm housing
PR 5333D 2-wire Programmable Transmitter
Input:RTD / Ohm
Ouput: 4...20 mA
Accuracy:Better than 0.1% of sel. range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal): IP68 / IP00
Ouput: 4...20 mA
Accuracy:Better than 0.1% of sel. range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal): IP68 / IP00
PR 4116 Universal Transmitter
Input:RTD / TC / Ohm / potentiometer / mA / V
Output:current, voltage and 2 relays
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C to +60°C
Relative humidity:< 95% RH (non-cond.)
Protection degree:IP20
Output:current, voltage and 2 relays
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C to +60°C
Relative humidity:< 95% RH (non-cond.)
Protection degree:IP20
PR 5333A 2-wire Programmable Transmitter
Input:RTD / Ohm
Output:4…20 mA
Accuracy:Better than 0.1% of sel. range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal):IP68 / IP00
Output:4…20 mA
Accuracy:Better than 0.1% of sel. range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal):IP68 / IP00
PR 5714 Programmable LED Indicator
Display:4-digit 14-segment LED
Input:mA / V / Ohm / RTD / TC / Potentiometer
Output:2 relays and analog
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C … +60°C
Protection degree (mounted in panel):IP65 / Type 4X
Input:mA / V / Ohm / RTD / TC / Potentiometer
Output:2 relays and analog
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C … +60°C
Protection degree (mounted in panel):IP65 / Type 4X
PR 4114 Universal Transmitter
Input:RTD / TC / Ohm / potentiometer / mA / V
Output:Current / voltage
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C … +60°C
Protection degree:IP20
Output:Current / voltage
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C … +60°C
Protection degree:IP20
PR 9116B Universal Converter
Input:RTD / TC / Ohm / Potentiometer / mA / V
Output:Active / passive mA output and relay
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20
Output:Active / passive mA output and relay
Accuracy:Better than 0.1% of sel. range
Operating temperature:-20°C ... +60°C
Protection degree:IP20
PR 6334A 2-wire Programmable Transmitter
Input:TC
Output:4…20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree:IP20
Output:4…20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree:IP20
PR 5437D 2-wire HART 7 temperature transmitter
Input:RTD / TC / Potentiometer / Ohm / mV
Output:3.8...20.5 / 20.5...3.8 mA
Operating temperature:-50°C ... +85°C
Accuracy:< ±0.1% of span
Protection degree (encl./terminal):IP68 / IP00
Output:3.8...20.5 / 20.5...3.8 mA
Operating temperature:-50°C ... +85°C
Accuracy:< ±0.1% of span
Protection degree (encl./terminal):IP68 / IP00
PR 5335D 2-wire transmitter with HART protocol
Input:RTD / TC / Ohm / mV
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00
Output:4…20 mA
Operating temperature:-40°C ... +85°C
Accuracy:Better than 0.05% of selected range
Protection degree (encl./terminal):IP68 / IP00
PR 5334A 2-wire Programmable Transmitter
Input:TC
Output: 4...20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal):IP68 / IP00
Output: 4...20 mA
Accuracy:Better than 0.05% of selected range
Operating temperature:-40°C ... +85°C
Protection degree (encl./terminal):IP68 / IP00
PR 5202B Pulse Isolator
Sensor types:NAMUR according to EN 60947-5-6 / mechanical contact
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20
Output:Relay / NPN
Operating temperature:-20°C … +60°C
Protection degree:IP20
PR 4510 Display / programming front
Programming display for all past and present 4000 / 9000 series devices, 3000 series devices where applicable, and all versions of ConfigMate 4590
Monitor process value and status from the built-in display
Scrolling help text in 7 languages
Monitor process value and status from the built-in display
Scrolling help text in 7 languages
PR 3108 Isolated repeater/splitter
Current input:Measurement range 0...23 mA
Current output:Signal range 0...23 mA
Accuracy:Better than 0.05%
Operating temperature:-25°C ... +70°C
Protection degree:IP20
Current output:Signal range 0...23 mA
Accuracy:Better than 0.05%
Operating temperature:-25°C ... +70°C
Protection degree:IP20