Flow transmitter

Flow transmitter, applied to flow monitoring in pipelines, includes flow meters and flow switches. Featuring hot-wire type and ultrasonic non-contact measurement, it is suitable for various types of liquids.

eyc-tech FTC06 Flow Transmitter

Features : Rugged aluminum housing, RS-485 temperature and water flow measurement, data logging, for liquid cooling systems.
Sensor type : Pt 50 / Pt 1000
Measuring range : 0 ... 3 m/s
Output : 4 ... 20 mA / RS-485 / NPN
Accuracy : ±2%
IP rating : IP65

eyc-tech FUM06 Ultrasonic Flowmeter

Features : Non-intrusive and high-precision measurement, suitable for various fluids and pipe sizes.
Sensor type : Ultrasonic time difference
Turndown ratio : 100 : 1
Measuring range : 0.1 ... 10 m/s
Output : 4 ... 20 mA / 0 ... 10 V / RS-485
Accuracy : ±1% F.S.
IP rating : IP65

Huba 237 Vortex flow sensor

Measuring range : 1,1 ... 240 l/min
Medium temperature : -15 ... 125°C (Non-freezing media)
Media : Heating water with standard additives; Drinking water
Accuracy :

Huba 210 Flow sensor for liquid media

Measuring range : 0,5 ... 150 l/min
Response time : 5 ... 500 ms
Media : Heating water with standard additives; Drinking water
Medium temperature : -15 ... 125 °C (Non-freezing media)

EGE SZAb 400 Flow Sensors

Output:Relay/change-over
Supply voltage:AC 230 V ±10%
Ex marking-GAS:II(1)GD [Ex ia] IIC
Ex marking-Dust:II(1)GD [Ex ia] IIIC

EGE SD 504 S Flow rate sensors

Medium:Water
Detection range:1 ... 1000 ml/min (0.001 ... 1 l/min)
Compressive strength:20 bar
Ambient temperature:-20 ... 70 °C
Protection rating:IP 67

EGE SDN 500 Series Flow Sensors

Output:PNP / Relay / Analog
Medium temperature:0...+80°C
Compressive strength:1 ... 20 bar
Protection:IP67

EGE SKM 420 GR/GA Flow Sensors

Output:Relay / PNP / 4 … 20 mA
Supply voltage :DC 24 V ±20%
Ambient temperature:-20 … +60℃
IP rating:terminal: IP 20 / housing: IP 40

EGE SC 440/1-A4-GSP Flow Sensors

Detection range:water 1...150 / oil 3...300 cm/s
Output:PNP
Sensor length L:48 mm
Thread:G1/2

EGE LNZ 450 GA-S Air Flow Sensors

Range:0.5 ... 30 m/s
Output:4 ... 20 mA
Medium temperature:-20 … +80°C
Compressive strength:30 bar
IP rating:IP67

EGE LN 520 GA Air Flow Sensors

Range : 0.5 ... 15 m/s
Output : 4 ... 20 mA
Medium : Air, non-explosive gas
Ambient temperature : -20 … +70°C
IP rating : IP67

HONSBERG Flow Transmitter VHZ

HONSBERG RT Flow transmitter

Sensor:biased Hall sensor
Nominal width:DN 15..50
Process connection:male thread G 1/2 A...G 2 A
Metering ranges:1.8..1133 l/min
Measurement accuracy:±1 % of full scale value
Medium temperature:-20..+85 °C / optionally -20..+150 °C (for 8 bar min.)
Ambient temperature:-20..+70 °C

Höntzsch Vortex Probeufa VA40…ZG10

MEDIA:gases
DISPLAYED INDICATORS:flow velocity / flow rate / volume
MEASURING RANGE:0.5 ... 40 m/s
SENSOR OUTPUT:analog output 4-20 mA / limit value / quantity pulse / RS232 interface
PRESSURE RESISTANCE:up to 3 bar / 300 kPa overpressure
MEDIA TEMPERATURE:-40 / -20 / 0 ... +100 °C
IP PROTECTION TYPE:IP65 (connection housing)

Höntzsch UFA Transducer UFA

SENSOR INPUT:v/FA / v/FAR
SENSOR OUTPUT:analog output flow 4 ... 20 mA or 0 ... 10 V flow-proportional, relay for limit value, quantity pulse or indication of +/- flow direction, RS232 interface
IP PROTECTION TYPE:IP20

Höntzsch ZS30 Vane wheel flow sensor

MEDIA:gases / liquids
MEASURING RANGE:0.3 ... 3 m/s in gases / 0.03 ... 3 m/s in liquids
PRESSURE RESISTANCE:up to 6 bar / 600 kPa overpressure
MEDIA TEMPERATURE:-40 ... +350 °C
DISPLAYED INDICATORS:flow velocity / flow rate / volume
IP PROTECTION TYPE:IP65 (connection housing)

Höntzsch ZS25 Vane wheel flow sensor

MEDIA:gases / liquids
MEASURING RANGE:0.4 ... 120 m/s in air/gases / 0.04 ... 10 m/s in water/liquids
PRESSURE RESISTANCE:up to 10 bar / 1 MPa overpressure
MEDIA TEMPERATURE:-40 ... +550 °C
DISPLAYED INDICATORS:flow velocity, flow rate, volume
IP PROTECTION TYPE:IP65 (connection housing)

Rheonik mass flow meter and Coriolis meter

Rheonik RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

MEASUREMENTS:Mass Flow / Volumetric Flow / Density / Temperature
FUNCTIONS:Batch / Filling Control / Standard Volume Gas Flow / Assurance Factor® / API std. Volume, Net Oil / Tamperproof Lock Switch
OUTPUTS:2 x Analog / 2 x Frequency / Pulse / 2 x Digital Status
INPUTS:2 x Digital / 1 x Analog
INTERFACES:PC USB / RHECom / RS-485 / Modbus RTU / HART over analog
APPROVALS:ATEX / IEC Ex / CSA